    May 23, 2008, 08:36 AM
    CFL bulbs dying prematurely
    Hi,

    We are using CFL bulbs quite successfully throughout the rest of our house, except in the dining room where we have now had 3 die on us within the last 4 months. I believe regular bulbs were dying in the same light fixture too. We swapped the light fixture for the same model and have been having the same issue.

    The CFLs had a bulb-style casing around the outside that appeared to crack where it met the contact area in one case and with the regular bulbs we had two where the glass separated from the contact area as well.

    Any ideas what could be causing this, I am not sure if its just a cheap fixture or if we have a wiring problem, but the CFLs are kind of expensive to keep replacing at this rate. The fixture is a contractor grade chandalier style which takes 5 bulbs and I believe was only $40 at Lowe's. Also, in at least one instance tapping the CFL caused it to come back on temporarily!

    Thanks!
    KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #2

    May 23, 2008, 08:53 AM
    Loose wiring can cause excessive heat. The wires in this case could be in the junction box in the ceiling or anywhere in the circuits feeding the lap. Another place to look is the switch itself.

    Vibration should not affect CFL's like it would conventional lamps.

    Have the wiring inspected if you can't do it yourself.
    KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #3

    May 23, 2008, 08:54 AM
    Loose wiring can cause excessive heat. The wires in this case could be in the junction box in the ceiling or anywhere in the circuits feeding the lap. Another place to look is the switch itself.

    Vibration should not affect CFL's like it would conventional lamps.

    Have the wiring inspected if you can't do it yourself.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

3 way bulbs [ 2 Answers ]

:rolleyes: what wattage do you get when you put a 3 way bulb in a one way socket

The cost for 1500 watt MH bulbs and Multitap ballast for MH bulbs [ 1 Answers ]

I need to know the cost of installation for 1500 watt MH bulbs and Multitap ballast for MH bulbs. Materiall cost will be beneficial. Barbara Ivory

Trane furnace turns off prematurely; valve gets very hot [ 1 Answers ]

Although my question sounds similar to other topics, this is very different. I think a gas valve component is getting abnormally hot! My furnace will turn on, the gas burners will light, and blower will turn on for about 5-10 minutes, enough to move the temp up 2 or 3 degress. Then the furnace...

HEIL Furnace Air Cycler shuts off prematurely [ 1 Answers ]

Hello, I have a HEIL furnace Mod# NTC6150KJA1. The air cycler timer is set for 30 minutes and once the time expires, the air cycler kicks on for about 3 seconds and then shuts off. It kicks on again 2 seconds later and stays on for 3 seconds and then shuts off. It continues this cycle for a...

What can cause asphalt shingles to prematurely lose aggregate? [ 10 Answers ]

I have a house built new in NJ in 1988. Roof is Tamko Heritage multilayer asphalt shingles. I believe that the warranty is 50 yrs. Shingles are over a plywood deck over an attic. Vents in each gable end, plus 2, 10-12" square roof vents. There also is an attic fan set to turn on when the attic...


View more questions Search