Ask Experts Questions for FREE Help !
Ask
    r2traps's Avatar
    r2traps Posts: 36, Reputation: 1
    Junior Member
     
    #1

    Feb 25, 2008, 10:34 AM
    Permanently removing sink: what plumbing work is needed?
    I have a sink in my basement which I would like to permanently remove. As far as plumbing goes, what would I need to do to permanently shut off the water supply?

    I've only done basic plumbing jobs, so I'm hoping the experts on here can help me with suggestions.

    I would guess that I would have to cut the drywall around the water pipes so I could cut the pipes adequately so they don't stick out of the wall. Then I would install shut off valves and leave it permanently closed. Then I would simply add drywall to cover the hole I made and patch it up. Am I on the right track?
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #2

    Feb 25, 2008, 11:42 AM
    Very close but no 100% yet. You may need to open the drywall to get inside to cut some pipes but shut offs should not be left permanently inisde a wall. Cap the supply pipe with a threaded cap if galvanized or a sweat cap if copper. You should remove the trap from the drain and the lateral to the drain stack. That too should be capped.
    r2traps's Avatar
    r2traps Posts: 36, Reputation: 1
    Junior Member
     
    #3

    Feb 25, 2008, 02:21 PM
    Thanks for the reply ballengerb1. I have copper lines so I would solder on a sweat cap. Wouldn't water still try to force itself through the supply pipe?
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #4

    Feb 25, 2008, 02:36 PM
    Sure it will and at about 45 psi but your soldered cap will hold that 24/7/365. Can't say that forever with a shut off valve. I am guessing your trunk line is 3/4" and the taps to supply the sink are 1/2". Cut the 1/2" pipe about 1" out from the connection to the trunk and solder a cap there. Easier and cheaper than trying to remove the Tee and splicing in a coupling.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Removing a wet bar sink [ 1 Answers ]

I need to remove a wet bar that we have in a closet. What do I need to do about the plumming parts.

Rough in Plumbing Help Needed [ 4 Answers ]

Hi everyone, I would like to rough in the following valves and would like some guidance. I contacted the manufacturer and they provided minimal help. While I do have experience having put in only 5 new baths for friends and family, some if these values type are new to me. Thanks The final...

Plumbing schematic needed [ 1 Answers ]

Does anyone know a good website to find help in putting together a plumbing schematic? I need to draw one so I can get a building permit for a remodel.

Removing utility sink [ 1 Answers ]

I will be removing a utility sink and cabinet and will not be replacing it. My question revolves around the drain coming out from the wall.The water lines have shut off valves which will remain in place in case the utility sink were to be needed at a later time so they are not the issue. Can I...

Plumbing - 1st floor sink backs up in sink below [ 3 Answers ]

I have a 1st floor kitchen sink directly above a basement sink. When the 1st floor sink is full, it drains quickly and backs up in the sink below - which then drains relatively quickly. No other problems here - the dishwasher drains fine, general use is fine - it's only when there's a full sink of...


View more questions Search