Jan 27, 2008, 03:30 PM
|
|
Angle stop repair/replace opinions
I need some ideas here.
There are two angle stops which are about 50 years old and they under a vanity have started to leak. I can’t turn them off.. I can’t tighten the packing nut. Actually the cold is leaking around the packing nut, but can’t turn either off.
They are long. There is about 3.5” of non-magnetic pipe which I assume to be chrome plated copper before it hits the actual valve body. I have my doubts whether the joint next to the valve can be unsweated. They are sweated about 1” from a ceramic tile wall.
The OD of the pipe leading to the stop is 0.679 and the OD of ½” copper tube is 0.614, so I don’t think I have options there.
I did replace one of these for a toilet some time ago and I’m comfy soldering that close to the tile with a barrier.
Some options:
Put ball valves downstairs where the pipes are easily accessible in any case.
I could try to rebuild the valve, but the last time I tried, it was futile trying to find parts. Installing ball valves downstairs would make me comfy to try doing this.
I could try to find one of these at a local plumbing supply house and re-sweat and add a ¼ turn aux valve if I want to. I found them online for $100. Seems too expensive. I remember them being cheaper, but it wasn’t ¼ turn.
I think my best option is to solder a female adapter to the 1” stub coming out of the wall. Then use a short threaded extension, either chrome or brass to a (female pipe thread to compression supply valve). ¼ turn if possible.
The attached picture shows the angle stop, taken with a circular mirror in the picture as well. The handle to the angle stop is removed.
What do you guys think.
KISS
|
|
 |
Junior Member
|
|
Jan 27, 2008, 03:32 PM
|
|
Ive had to replace many of those in motel rooms that I have worked on... you have to buy new valve (compression works best) and new water line
|
|
 |
Home Improvement & Construction Expert
|
|
Jan 27, 2008, 04:22 PM
|
|
I'm confused. Copper is magnetic, steel is magnetic. Installing stop valves downstairs will give you the ability to turn off the water to the sink but they won't stop the leak around the valves. Those valves don't look soldered from here, could they be threaded. Posting pics is the most helpful thing you could have done.
|
|
 |
Junior Member
|
|
Jan 27, 2008, 04:24 PM
|
|
The valve body is soldered not the water line
|
|
 |
Senior Plumbing Expert
|
|
Jan 27, 2008, 05:22 PM
|
|
Hey KISS... Hey... unsweat those babies and should be able to sweat a new set on pretty easy... if I get this post right. In my area they sell a brasscraft angle stop exactly as pictured for about 11.00 each (found at home depot and plumbing supply stores).
Clean the sweat joint under the bell flange real well... re-flux and should pop of pretty easy.(pulling handle and stem clear out of the valve helps).. heat and wipe a few times to clear heavy solder off after unsweating and then sand cloth the pipe and re-flux. Then add the valves... remove chrome plating from end of area to be soldered (will be under new bell flange) and sweat ' them on.
I hope this is what you were talking about... I do remodeling all the time and see this valve a lot!! Good luck.
|
|
 |
Uber Member
|
|
Jan 27, 2008, 05:26 PM
|
|
Copper is not magnetic. Meaning it's chrome plated copper because there is some copper showing near the wall.
When I replaced the toilet valve, the unit that's replaced consists of a piece of chromeplated copper attached to the angle valve. With the chrome plating at the stop it would be difficult to remove or resolder at that joint. It must be removed where it's soldered, which is about 1" from the wall.
The unit is plated at the junction of the chrome pipe and the valve, so you have no way of knowing how it's attached.
But putting the ball valves downstairs allows me to address the problem without having the parts for plan B available.
e.g. Plan A
Install ball valve on hot water supply. Easy.
Turn off hot water with ball valve. Remove stem and address the posibility of a rebuild.
It's easy to go without hot water in the lavatory sink for many weeks.
Plan B
Replace the stop.
|
|
 |
Uber Member
|
|
Jan 27, 2008, 05:29 PM
|
|
Mp:
That's what I did before. The ceramic tile makes it interesting but doable with the right tools.
I'm just thinking that the other choice sounds like a better idea. Female adaper + chrome pipe + angle stop. It then should be easy next time. If there ever is a next time. Also the bell can be replaced easily.
That's the option I need evaluated providing I can't rebuild the valve.
|
|
 |
Senior Plumbing Expert
|
|
Jan 27, 2008, 05:40 PM
|
|
I'm sorry... I got so excited by the pic I only read about 3/4 of post... *laugh*... My opinion (for what it is worth... )... go for it!! Female to nipple to shutoff never fails!! Take care KISS
|
|
 |
Home Improvement & Construction Expert
|
|
Jan 27, 2008, 06:50 PM
|
|
I stand corrected. Before I posted I went to check. My magnetic pick tool picked up copper mounting strap. Should have check against piece of copper pipe. Strap is copper plated steel.
|
|
 |
Ultra Member
|
|
Jan 27, 2008, 07:43 PM
|
|
[QUOTE=KeepItSimpleStupid]
The OD of the pipe leading to the stop is 0.679 and the OD of ½” copper tube is 0.614, so I don’t think I have options there.
I'm betting the difference in thickness is due to the chrome plating.
Try removing some of the plating to see if the circumference changes enough to accommodate the installation of compression angle stops.
|
|
 |
Uber Member
|
|
Jan 27, 2008, 08:22 PM
|
|
Growler: I think 0.032 is a little thick for plating (0.679-0.614)/2
Mp: That's what I figure. Everything becomes easier.
Hopefully, I can repair the valve. Easier yet.
|
|
 |
Uber Member
|
|
Jan 29, 2008, 01:12 PM
|
|
Well, did some research today at Lowes:
No 1/2" pipe deep flanges available.
Checking with a 1/2" tube flange, the female adapter thing at the wall won't work. It won't hide under the flange.
Only straight long supply valves available there.
So, I'm going to go ahead with the ball valve install. Figure out what size the compression supply is and attempt to find the appropriate angle stop that I need from a plumbing supply store if re-building doesn't work.
Get a short, right angle, torch to work in the confined space if needed.
|
|
 |
Senior Plumbing Expert
|
|
Jan 29, 2008, 04:14 PM
|
|
KISS.. this is under a vanity... right? So who cares if female adapter doesn't fit under bell flange? There will be all kinds of stuff piled in front... yes... no?
Anyway... ball valve idea is fine... rebuilding is even better... but one last thought.. for what it is worth.
CUT the bell flange off completely... use a red pair of aviator snips... cut as far as you can go and then kind of twist to finish cutting and pull off (gently)... very thin metal. THEN UNSWEAT that baby as I said before... use sandcloth and 1/2" copper wire cleaning brush to clean that sweat joint real good..then flux it..then heat it in about 1" to start... then work your way back toward solder of joint.. twist and pull off (I know you have done 1, but can't hurt to repeat these steps for anyone).
THEN... reflux... reheat and with a rag wipe that copper pipe clean of all solder until no longer gunked on (do not overheat this pipe... could loosen a joint behind wall).. then when cooled sandcloth it to leave behind just a slight tinted copper pipe. THEN you either add a 5/8" compression x 3/8" compression chrome angle stop with a flat escutcheon behind it... OR, you could just sweat a new short chrome shutoff and use a flat escutcheon... no one will see it.
Again... just thinking aloud with you. Cut that bell flange off... and see what you think from there. Always... best of luck!!
|
|
 |
New Member
|
|
Jan 29, 2008, 06:16 PM
|
|
 Originally Posted by KeepItSimpleStupid
I need some ideas here.
There are two angle stops which are about 50 years old and they under a vanity have started to leak. I can’t turn them off.. I can’t tighten the packing nut. Actually the cold is leaking around the packing nut, but can’t turn either off.
They are long. There is about 3.5” of non-magnetic pipe which I assume to be chrome plated copper before it hits the actual valve body. I have my doubts whether the joint next to the valve can be unsweated. They are sweated about 1” from a ceramic tile wall.
The OD of the pipe leading to the stop is 0.679 and the OD of ½” copper tube is 0.614, so I don’t think I have options there.
I did replace one of these for a toilet some time ago and I’m comfy soldering that close to the tile with a barrier.
Some options:
Put ball valves downstairs where the pipes are easily accessible in any case.
I could try to rebuild the valve, but the last time I tried, it was futile trying to find parts. Installing ball valves downstairs would make me comfy to try doing this.
I could try to find one of these at a local plumbing supply house and re-sweat and add a ¼ turn aux valve if I want to. I found them online for $100. Seems too expensive. I remember them being cheaper, but it wasn’t ¼ turn.
I think my best option is to solder a female adapter to the 1” stub coming out of the wall. Then use a short threaded extension, either chrome or brass to a (female pipe thread to compression supply valve). ¼ turn if possible.
The attached picture shows the angle stop, taken with a circular mirror in the picture as well. The handle to the angle stop is removed.
What do you guys think.
KISS
You need to buy new compression valves and new water lines. You can find everything you need at Home Depot.
|
|
 |
Ultra Member
|
|
Jan 29, 2008, 09:08 PM
|
|
 Originally Posted by KeepItSimpleStupid
I need some ideas here.
There are two angle stops which are about 50 years old and they under a vanity have started to leak. I can't turn them off.. I can't tighten the packing nut. Actually the cold is leaking around the packing nut, but can't turn either off.
They are long. There is about 3.5” of non-magnetic pipe which I assume to be chrome plated copper before it hits the actual valve body. I have my doubts whether the joint next to the valve can be unsweated. They are sweated about 1” from a ceramic tile wall.
The OD of the pipe leading to the stop is 0.679 and the OD of ½” copper tube is 0.614, so I don't think I have options there.
I did replace one of these for a toilet some time ago and I'm comfy soldering that close to the tile with a barrier.
Some options:
Put ball valves downstairs where the pipes are easily accessible in any case.
I could try to rebuild the valve, but the last time I tried, it was futile trying to find parts. Installing ball valves downstairs would make me comfy to try doing this.
I could try to find one of these at a local plumbing supply house and re-sweat and add a ¼ turn aux valve if I want to. I found them online for $100. Seems too expensive. I remember them being cheaper, but it wasn't ¼ turn.
I think my best option is to solder a female adapter to the 1” stub coming out of the wall. Then use a short threaded extension, either chrome or brass to a (female pipe thread to compression supply valve). ¼ turn if possible.
The attached picture shows the angle stop, taken with a circular mirror in the picture as well. The handle to the angle stop is removed.
What do you guys think.
KISS
Y'know, there has been something very unsettling about this thread from the get-go, and I've finally realized what that is...
The outlet on the stop is 3/8" OD, which doesn't fit with the '50 years old' statement you made in your initial post -- If they were 50 years old, the outlets would be 5/16" OD , 3/8" ID or 1/2" OD.
Is it possible those are 3/8" IPS nipples with the stops machined on?
I've come across just such an animal in the past, usually as kit's sold for wall hung or pedestal lavs where the stops came already machined onto 6" brass 3/8" nipples.
>shrugs<
Just a thought.
|
|
 |
Uber Member
|
|
Jan 29, 2008, 09:58 PM
|
|
I never said what the outlet of the stop is. I haven't looked.
In the wall there is an unrestrained 1/2" elbow. Sticking out from the elbow is about an 1" worth of copper pipe. To this 1" of copper pipe there is sweated to what's shown in my picture. The sweated joint is under the bell.
If I overheat the 1" piece of copper, I risk losing it in the wall.
It's similar to this pricey item: Mountain Plumbing Products 1/2" Copper Sweat Inlet x 3/8"O.D. Compression Outlet Deluxe Cross Handle Angle Valve - MT4006X : Homeclick
I saw straight versions at Lowe's for about < $15.
Your right, I could take even another approach:
Unsweat the current angle stop. Add a coupler and extend the copper pipe and use a compression angle stop, but I probably wouldn't be able to find a large bell to go over the coupler, but I could use a flat cover that doesn't have to go over the pipe before it's soldered.
Hey, I like things to look nice too, even if they are covered most of the time.
Is it possible those are 3/8" IPS nipples with the stops machined on?
Don't think so. The plating is continuous with no sign of threads.
|
|
 |
Ultra Member
|
|
Jan 30, 2008, 07:40 AM
|
|
 Originally Posted by KeepItSimpleStupid
I never said what the outlet of the stop is. I haven't looked.
Well, I did, it's in the photo you uploaded.
In the wall there is an unrestrained 1/2" elbow. Sticking out from the elbow is about an 1" worth of copper pipe. To this 1" of copper pipe there is sweated to what's shown in my picture. The sweated joint is under the bell.
Right -- The chrome tube you see sticking out of the wall with the stop attached to it is 5/8" ID copper tube size.
IOW, it has the same outside diameter of a 1/2" copper fitting.
If I overheat the 1" piece of copper, I risk losing it in the wall.
So why would you do that?
Just cut the chrome tube behind the stop, clean the inside with a fitting brush solder a 2" piece of copper into it and install a 1/2"x3/8" compression angle stop.
It won't be pretty, but it is inside a vanity, as opposed to being a pedestal or wall hung lavatory.
Y'know, I'm all for doing the job right, but to do so would require removing the back panel of the vanity, opening up the wall and re-roughing in the water supply.
If the homeowner balks at this approach, then do the very best job you can with what you have and move on to the next one.
Just my two pence.
|
|
 |
Junior Member
|
|
Jan 30, 2008, 11:50 AM
|
|
 Originally Posted by massplumber2008
THEN UNSWEAT that baby as I said before...use sandcloth and 1/2" copper wire cleaning brush to clean that sweat joint real good..then flux it..then heat it in about 1" to start...then work your way back toward solder of joint..twist and pull off (I know you have done 1, but can't hurt to repeat these steps for anyone).
THEN...reflux...reheat and with a rag wipe that copper pipe clean of all solder until no longer gunked on (do not overheat this pipe...could loosen a joint behind wall)..then when cooled sandcloth it to leave behind just a slight tinted copper pipe.
MASSPLUMBER-
I am interested in your comments for a related issue.
It looks like your process to unsweat a joint is to clean it well, flux, THEN heat to melt joint and twist off the fitting, correct? Also, it looks like you have no issue with then re-soldering at the same joint.
I have a 1" elbow that did not seal completely; it was 10° and windy. ( My joints inside look fine). I'm going to wait for a warmer (25°) day to re-do. Should I remove the elbow and start over, or just heat it up and add more solder?
Thanks!
|
|
 |
Senior Plumbing Expert
|
|
Jan 30, 2008, 03:02 PM
|
|
Hey pdw77.. I would definitely sand, flux, heat, pull elbow off (twist a little). Then, re-heat slightly and with a rag wipe the excess solder off until left with a slightly tinned/ copper finish on the pipe. Then let cool and clean again with sandcloth... re-flux, clean/flux fitting ( I would use a new elbow as well.. just increase odds of finishing the job at this point... but if not available and you did not destroy it getting it off... well then you could just clean/flux this.. and reheat the elbow to slide onto the pipe... then solder both pipe and fitting... should do it) and join fitting to pipe and then solder away. That should pretty much guarantee success!
Hey let me know if this helped!! Good luck.
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Hissing Angle Stop
[ 1 Answers ]
We just had the angle stops for all of our toilets as well as the flushing mechanisms replaced just over 2 months ago. Now the angle stop in our master bathroom is hissing when the tank is filling back up with water. Any ideas on how to fix it?
If I turn down the wate pressure, it does stop...
Angle stop leaking
[ 3 Answers ]
I recently installed new "fill valve & flapper" to my toilet. Basically all of the insides of the toilet. It was leaking at the bottom of the toilet so I added a washer wich fixed that leak, but now it leaks at the angle stop. I bought some teflon tape to use to try to use at the connection of...
Installing angle-stop
[ 3 Answers ]
I need to replace my angle-stops for my kitchen sink. Never done it before. It seems easy, but I want to make sure before I do it, that I'm doing it correctly. Appreciate it, in advance.
Angle stop valve
[ 3 Answers ]
Do you have any idea on how to install a stop valve under a bathroom sink?
Thanks R. Koehn
Angle stop
[ 3 Answers ]
What is a standard 1/2" compression angle stop? I am installing a sink faucet supply line
View more questions
Search
|