    Sewer vent frosting over
    I live in Minnesota and my sewer vent on my roof will frost over when it gets really cold out, sending sewer odor in my house. Do you know if there is anything to do to keep it from frosting over?
    doug238's Avatar
    doug238 Posts: 1,560, Reputation: 62
    Ultra Member
     
    #2

    Jan 25, 2008, 05:10 PM
    Heat tape
    dreside's Avatar
    dreside Posts: 1, Reputation: 1
    New Member
     
    #3

    Dec 4, 2010, 11:58 AM
    I live in Canada and had a simliar problem, I learned a trick from a local plummer. If you bring the pipe up to the prescribed height and then put 2 90 degree fittings on (so it looks like an upside down J) no snow can get in the pipe and any moisture from melted snow etc will fall out, rather than gathering on the rim of the pipe and freezing, last year I had an actual ice plug in the pipe from similar problem, but the above solved it.
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #4

    Dec 4, 2010, 12:04 PM

    Do this: Buy cheap electric blanket. Wrap it around the pipe in the attic. Make sure entire exposed vent pipe is nicely wrapped. Tape it over with duct tape so blanket won't slip down. Blanket should cover this vent all the way under the roof. Plug cord into timer, set time of operation and turn it ON. The blanket will keep the pipe worm and will prevent ice from accumulating inside the pipe. That will do...
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #5

    Dec 4, 2010, 12:07 PM
    Quote Originally Posted by ;
    put 2 90 degree fittings on (so it looks like an upside down J)
    A more simple solution would be to install vent caps, (See image) on your vents. Good luck and stay warm. Tom
    Attached Images
     

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

All my toilets smell like a sewer! Sewer backed up? [ 4 Answers ]

Hello all, I have a problem and was hoping for some guidance... lately all of my toilets have been smelling really bad. We have 3 toilets in the house, 2 full baths on the upper level, and a powder room on the main. The main bath on the upper level is the worse of the 3. It doesn't get...

Sewer gas - did I hook up to main sewer line correctly? [ 3 Answers ]

Moved a mobile home in and ran the sewer line to the main line - on some days I smell sewer gas, and I think it's coming from the vents on the house! - I want to know if I should o had put a "P" trap or something in line before hooking up to main sewer line? I have seen other places saying to...

Vent diagram - does this meet code (see pic)? Vent runs below actual drain [ 4 Answers ]

The schematic below should make it clear the configuration I would like to use. Basically, I would like to keep the vent under the floor for a little ways, so it pops up in a better location. I cannot easily move the 2" drain location going down and would rather not go straight up from the...

Sewer vent. [ 1 Answers ]

I have a 4 inch sewer pipe going to a septic system. The pipe exits throgh the floor into the knee wall of the second floor of an unfinished room after renovations. I extended it into the crawl space in the attic by running it along the rafters in a roof pitch. I downsized it to a 3 inch pipe...

Sewer line vent [ 1 Answers ]

I replaced all the sewer line in my home. The only way to flush toilet is to unhook drian line to upstair sink to get it to flush. Otherwise toilet back up and then very slowly drains. Does this mean the vent is plugged? My line also goes into s septic tank.


View more questions Search