    Reddy R155 kerosene heater
    I used my R155 kerosene heater for years in my garage without any problems. Then the 097061-01 solid state relay went out. I replaced it with new part number 107850-01. At the same time, I also figured I would replace the filters & gasket (HA3017) and the rotor (HA3004). When putting it back together, I used the HA1182 low pressure gauge I bought to set the psi to 5.0 psi like the manual said. Upon doing this, it would only blow out a cloud of atomized kerosene and not light. If I put my finger over the adjustment screw and let the pressure increase toward 10 psi, it would light but then go out as it returned to 5.0. I tried increasing the pressure. At ~6 psi would allow it to stay lit but your eyes burned from unburnt kerosene as it ran longer and longer. I decided to replace the other components related to the fuel air mixture (HA3010 nozzle and PP211 spark plug). No improvement. I increased the pressure to 8.0 psi which made the end cap glow slightly but it would stay lit and not put out a cloud as it tried to start.

    Can you help give me some guidance as to what is wrong or what to check??
    MOWERMAN2468's Avatar
    MOWERMAN2468 Posts: 3,214, Reputation: 243
    Ultra Member
     
    #2

    Jan 21, 2008, 06:29 AM
    Have you inspected the air filter located at the rear of the heater? What about the fuel filter located inside the tank? Sounds like you are working toward the price of just replacing the whole unit. Be careful and not spend too much on the current heater.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Sears kerosene portable heater [ 1 Answers ]

I wanted to know how to change the wick . I took it all apart and cleaned it up ,but I still couldn't get the wick out of the holder. Thanks bjkennel

Kerosene Heater [ 2 Answers ]

How do you raise wick in a Dyna-Glo RMC-55-R7 Kerosene Heater?

Manually extinguishing kerosene heater? [ 5 Answers ]

I'm sure by the time this gets answered I'll have burned the kerosene tank dry... but just in case it happens again... I replaced the wick today in my Dyna-Glo Kerosene (RMC-55-R7) heater, put it back together, filled the tank, let it set for an hour, and lit it up. I thought everything was...


View more questions Search