New Member
|
|
Jan 4, 2008, 11:16 AM
|
|
Nosie in Pipes
We have oil heating in the house we just bought. The radiators work fine downstairs, but upstairs is FREEZING. The radiators use to heat up, but now they don't all the time. Every time the boilers goes on it sounds like water is draining in the pipes and I can hear it in the wall. Any suggestions? Thank you.
Michelle
|
|
 |
Ultra Member
|
|
Jan 4, 2008, 04:23 PM
|
|
There is air in the system it sound like the upper radiators need the air bled out of them. It is not easy for me to tell you the best way to do it, hopefully there are little bleeder screws on the second floor radiators, that is the easiest to bleed.
|
|
 |
New Member
|
|
Jan 4, 2008, 08:04 PM
|
|
We bled the radiators upstairs. Some air comeout but then nothing. I was expecting water to follow, but the radiator is still cold. The one in the other room up there does have heat coming out of it. Any other suggestions? Thank you.
|
|
 |
Ultra Member
|
|
Jan 4, 2008, 08:52 PM
|
|
Is the pump working? If the boiler sounds like it is perculating like an old time coffee pot the pump[ may be bad
|
|
 |
New Member
|
|
Jan 5, 2008, 07:32 AM
|
|
No I think the pump is fine. All of the other radiators in the house are fine. I think there may be a block to that certain radiator. How would I fix that if that was the case? It still sounds like water is draining out of pipes from that radiator sometimes. I can hear the water going through the pipes in the wall downstairs.
|
|
 |
Ultra Member
|
|
Jan 5, 2008, 08:50 AM
|
|
What is the pressure? Should read 12-15 psi. Pressure reducing valve may be bad and not letting water into boiler.
|
|
 |
New Member
|
|
Jan 6, 2008, 09:37 AM
|
|
 Originally Posted by NorthernHeat
What is the pressure? Should read 12-15 psi. Pressure reducing valve may be bad and not letting water into boiler.
I had similer problem in one of the radiator. End up bleeding air and still no hot water and guess what... I incresed pressure to 20 psi.. all noise disppear and got hot water in radiator.. becareful. Don't go more than 20 psi
|
|
 |
New Member
|
|
Jan 6, 2008, 07:32 PM
|
|
If you bled radiators and air came out and than nothing,no water or nothing I will bet pipes are frozen...
|
|
 |
New Member
|
|
Jan 7, 2008, 07:01 AM
|
|
Could the pipes be frozen if all the other rads work and I can hear water draining from them?
|
|
 |
Ultra Member
|
|
Jan 7, 2008, 03:10 PM
|
|
They problem is low water and air in the lines...
|
|
 |
New Member
|
|
Jan 7, 2008, 05:08 PM
|
|
 Originally Posted by NorthernHeat
They problem is low water and air in the lines .........
your right was thinking 2 zone system...
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Frozen pipes - detecting burst pipes
[ 1 Answers ]
Cold side of the kitchen faucet was frozen this a.m.
Trickle returned this evening, followed by an immediate drop in hot faucet pressure - then some brownish water - the brownish water lasted 20 seconds - but the pressure is still low
1/3 pressure now and can get both some hot and some cold
Have...
Roaring pipes?
[ 1 Answers ]
This is a home that was built back in the late 60's/early 70's. Initially the first thing I noticed is with the basement toilet. It sounded like it was flushin' or refillin' on it's own. Now when it does that the pipes (I'm guessin' the pipes) seem to roar/whine. I've checked the water level in the...
Old Pipes
[ 4 Answers ]
I'm redoing a bathroom in a 1960's vintage home. Wanted to replace the rusted pipes draining from the sink (in the wall) with pvc. Should I screw out the pipe or just pull. Do I have to knock out the wall and get a clear view or can I do the job without wall damage. When I install the PVC do I...
View more questions
Search
|