    Heart Pump pulseing on and off
    I have an older Trane heat pump (about 16 years old). The air handler is in the attic. It has started pulsing on and off like a heart beat. I can hear a click from the air handler when it does this. When this is happening the unit outside is also pulsing and the outside fan is starting and stopping. It's a rhythmic pulse (on and off every second.) Sometimes it does it when I first turn it on, or it starts after it has been running awile. It seems to be getting worse. What could it be.

    Thanks Jeff
    Stratmando's Avatar
    Stratmando Posts: 11,188, Reputation: 508
    Uber Member
     
    #2

    Dec 21, 2007, 07:32 AM
    Wonder if a short in control wiring, or shorted coil on contactor. Loading down voltage to coil, releasing, going on, conducting(loading down) and repeating. See if you can measure
    24 volts from transformer and see if it "Pulses"?
    Also Measure 240 Volts, and see that it remains High, An amprobe can show if a load on the 240 volts side is drawing so much that the 24 volts also drop, dropping out relays or contactors.
    acetc's Avatar
    acetc Posts: 1,004, Reputation: 79
    Ultra Member
     
    #3

    Dec 21, 2007, 02:08 PM
    In addition to what Stratmando said you may be low on refrigerant and cycling on a low pressure control, good luck, Mike
    jbat's Avatar
    jbat Posts: 4, Reputation: 1
    New Member
     
    #4

    Dec 21, 2007, 04:20 PM
    Quote Originally Posted by jbat
    I have an older Trane heat pump (about 16 years old). The air handler is in the attic. It has started pulsing on and off like a heart beat. I can hear a click from the air handler when it does this. When this is happening the unit outside is also pulsing and the outside fan is starting and stopping. Its a rythmic pulse (on and off every second.) Sometimes it does it when I first turn it on, or it starts after it has been running awile. It seems to be getting worse. What could it be.

    Thanks Jeff
    Thanks guys. I guess Ill have to call a repairman.
    Stratmando's Avatar
    Stratmando Posts: 11,188, Reputation: 508
    Uber Member
     
    #5

    Dec 21, 2007, 08:03 PM
    Does it do it on heat, cool , or both? Don't Pay someone yet.
    jbat's Avatar
    jbat Posts: 4, Reputation: 1
    New Member
     
    #6

    Dec 22, 2007, 05:00 AM
    Quote Originally Posted by Stratmando
    Does it do it on heat, cool , or both? Don't Pay someone yet.
    I have not tried it on the cooling. Ill try it today sometime.

    Jeff
    jbat's Avatar
    jbat Posts: 4, Reputation: 1
    New Member
     
    #7

    Dec 22, 2007, 09:20 AM
    Quote Originally Posted by Stratmando
    Does it do it on heat, cool , or both? Don't Pay someone yet.
    I switched it to the cool side and it immediately started clicking on and off. The air handler fan stays running but the unit is clicking or switching on and off. Sound like a solinoid clicking.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Heart To Heart (BBC News) [ 4 Answers ]

Hello fellow AMHD Devotees, Just thought I'd share this news story with everyone as I thought it was pretty fantastic! BBC NEWS | Health | Woman face-to-face with own heart Goes to show how important organ donation can be! :) And this one, that literally made my skin crawl;

The Heart [ 1 Answers ]

Okay, I have two questions The first is:Does blood flow to the heart muscle during contraction or relaxation? The second is:What are problems associated with a hole in the heart? Thanks:)


View more questions Search