Teflon or Pipe Dope for 1 1/4" Water Pipe
I am building a project that uses several joints of 1 1/4 " galvanized pipe, including elbows and Tee's. The unit will be plumbed into my 50 psi water system. What is the best way to seal the pipe joints? I have assembled the unit and tested using teflon pipe dope and had several leaks.
|
|
 |
Ultra Member
|
|
Dec 12, 2007, 06:54 PM
|
|
The teflon wraps should be at least 5 and up to 10. I use 8 on most threads. It also needs to be tight enough.
|
|
 |
Uber Member
|
|
Dec 12, 2007, 11:26 PM
|
|
Doesn't the directions say 2 layers? I like Pipe-X by Loc Tite. I find it in auto parts stores.
|
|
 |
Eternal Plumber
|
|
Dec 13, 2007, 05:40 AM
|
|
Like Labman, I give the threads a couple of wraps of Teflon Tape with the threads. Some plumbers use more but two wraps is the minimum. Regards, btom
|
|
 |
Ultra Member
|
|
Dec 13, 2007, 02:13 PM
|
|
It has been my experience that most plumbers I have spoken with use 5 wraps. I went to 8 or 10 when I had leaks on the top of a water heater with 5 wraps. I absolutely do not get leaks with 8 wraps and I get the joint very snug but not cranked. If 2 works for you then I am OK with that for you. I get teflon tape for 19 cents per roll. I can afford to splurge. [smilez]
|
|
 |
Junior Member
|
|
Dec 13, 2007, 02:28 PM
|
|
1-check to insure the threads are continuous without chips and gaps that occur when you use cheap pipe,cut threads with dull blades creating bad threads.
2-wrap threads with quality teflon wrap, some wrap is rated for gas (yellow) and some are thicker then others, I use a good quality thick wrap with a couple of wraps around the threads in a clockwise rotation for right handed threads and visa versa for left handed threads, this keeps the teflon wrap from unwrapping when you tighten the joint.
3-Then to be sure I use a teflon paste also around the tape I don't like leaks because its just too time consuming breaking joint apart and doing them again & again. So spend the extra $ use quality products and take all precautions
|
|
 |
Ultra Member
|
|
Dec 13, 2007, 05:10 PM
|
|
I'm not a big fan of teflon tape.
La-Co Slic Tite is pretty much the only thread sealant I use anymore.
|
|
 |
Uber Member
|
|
Dec 13, 2007, 08:16 PM
|
|
When I was managing a factory, my guys weren't much at pipe fitting. The one could do oil tight welds. I picked up a head for our threader that would cut the grooves for Victaulic style couplings. That cut our oil dry bill way down.
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Adding a PVC "Y" to a underground Cast iron pipe
[ 1 Answers ]
I have a house built in 1962. The cast iron waste pipe runs under the concrete slab in the basement. I have already dug and confirmed the location I want to cut a section out of the pipe and install a "Y" connector and run new plastic waste pipes to a new bath. I have seen PVC connectors that...
Hot water pipe touching fire sprinker pipe
[ 6 Answers ]
I discovered why the water pressure in my fire prinkler system kept rising. It's because the hot water pipe is right up against the sprinkler pipe causing it to heat which then increases the pressure. Now can I wrap the pipe with insulation. Would this be a good fix? If so, should I wrap the hot...
Sealant (pipe dope) on faces of union
[ 3 Answers ]
I have a union that I just can't get to seal. The fluid in the pipe is off-road diesel fuel. The pressure is less than 50 psi. The fitting is a 1-1/2 npt iron union with a brass face.
I'm getting desperate. I'm thinking about disassembling it (yet again... ), drying it off, and applying a...
Broken Concrete trap "Drainage Pipe"
[ 1 Answers ]
I recently bought a house with a unfinished basement bath. I have since decided to finish the bathroom but have ran into a bit of a problem. The previous owners set all of the drains up and I have since found a large hole in the trap of a secondary drain that drains into the main. To explain it...
Tub to Shower 1.5" pipe to 2"pipe
[ 6 Answers ]
Shower uses a 2" pipe. Tub used a 1.5 inch pipe. Bought a 2"pipe coupler... using the coupler to attach the new 2" pipe to the old 1.5 inch joint on the 3" main house drain pipe.
The coupler has too much play on the 1.5 inch side... almost like it's an 1/8th of a inch smaller than 1.5. What's...
View more questions