Ask Experts Questions for FREE Help !
Ask
    peeps4life's Avatar
    peeps4life Posts: 21, Reputation: 1
    New Member
     
    #1

    Dec 3, 2007, 11:30 PM
    3 white wires twisted together from outlet box
    I am trying to install a new light fixture where I had a ceiling fan. The problem I have is that the light fixture I am using has a "fast attach receptacle". The box where the old fixture was has a bare ground wire, a black wire, and 3 white wires twisted together. The white wires twisted together do not fit into the opening on the fast attach female receptacle.

    What could be a solution for this?
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #2

    Dec 4, 2007, 03:53 AM
    Use a wirenut large enough for these three wires plus an additional short pigtail to attach to the connector.

    Usually red wirenuts will fit.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

3 white wires? [ 7 Answers ]

I was trying to install a "recycled" ceiling fan/light fixture and when I took the old fixture off I saw 3 white wires bundled together. The white wire from the old fixture was attached to that bunch and the black was on black. When I test the wires, 2 of the white wires run the electricity on...

GFI-6 wires to one outlet [ 1 Answers ]

My question is that I have an outlet in the bathroom right next to the sink. (Big NO NO) This outlet has 3 whites to it and 3 blacks to it with the proper grounds. This would place it in the middle of a series. How do I distinguish the line and the loads to replace the outlet with a GFI Outlet??...

Ceiling Fan light wires are Red and White? [ 1 Answers ]

I am installing a Harbor Breeze light kit with instructions that say attach the white wire from the kit to the white wire from the fan and the black wire from the kit to the blue wire from the fan. There are two unused wires inside the fan that were labeled For Light with a sticker that went...

Multiple white wires from old ceiling fan [ 1 Answers ]

Hello, We have just removed a very old ceiling fan and are attempting to replace it with a hanging fixture. However, there are THREE bundled white wires coming from the ceiling box. Do we attach the white wire from the fixture to the bundle? Or do we have to determine which wire from the box...

Open neutral - 3 wires; white as hot? [ 1 Answers ]

OK, I've encountered an oddly wired outlet in my kitchen and am trying to replace it with a GFCI. I unwired the old outlet, taking note of where things were attached, just in case. I wired the GFCI acoording to instructions and then checked the wiring with a Sperry GFI checker. All seemed OK. ...


View more questions Search