Ask Experts Questions for FREE Help !
Ask
    yoyo710's Avatar
    yoyo710 Posts: 2, Reputation: 1
    New Member
     
    #1

    Nov 7, 2007, 03:45 PM
    Washer dryer blow cold air after normal working 5 min.
    My Whirlpool gas dryer ( 6 years old ) blow cold air after normal start working 5 minutes.
    Check flame from panel hole ( normal ), no clog on vent,short hi limit thermostat
    After flame cut off try to restart, I saw ignitor glow but after 3 second then go out, I have to wait for a while then whloe thing repeat again
    Here is my question
    How to check flame sensor or coli for the valve ( I saw someone post the same question
    And fixed by replaced coil )

    Need help and many thanks!!
    applsvcgirl's Avatar
    applsvcgirl Posts: 112, Reputation: 9
    Junior Member
     
    #2

    Nov 7, 2007, 07:04 PM
    Before we condemn any parts let's do a test. Start the dryer and observe the flame in the cone. Now stop the dryer. Remove the vent tube off the back of the dryer and start it again. Observe the flame again. Does it look the same? Does it stay lit for the same amount of time? If so or if I am misunderstanding your post try this test next. Start the dryer and let it cycle the flame on repeatedly. If after several cycles the ignitor comes on and goes out without the burner lighting you do need coils. The flame sensor is OK regardless since the ignitor is lighting and going out when the burner lights. If you need more help or if I misunderstood your post feel free to contact me again.
    yoyo710's Avatar
    yoyo710 Posts: 2, Reputation: 1
    New Member
     
    #3

    Nov 8, 2007, 01:07 PM
    After replace pair coil ( $24.96 ) everything go back to normal, Great!
    My lady give me a big hug seems like I am a hero

    I want to thank Applsvcgirl faithfully to serve this site and very detail answer all the question, it's really helpfully , you are the man

    Best Regard

    David
    applsvcgirl's Avatar
    applsvcgirl Posts: 112, Reputation: 9
    Junior Member
     
    #4

    Nov 8, 2007, 06:11 PM
    Glad I could help!

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Everything is working furnace is blowing cold air [ 3 Answers ]

Hello we just bought a house this summer and we have a Olsen gas Furnace in our basement Apt. when we kick it on it is only blowing cold air everything seems to be working fine except the cylinder things on the front of the furnace r not lighting up and I think they r suppose to what could this...

Trane gas furnace only blow cold air [ 3 Answers ]

My 10 years old trane gas furnace would not blow out warm air, only cold air. I checked gas is on and electric switch is on. Every thing seems normal. It may be the ignition problem. How can I find out? Your help is greatly appreciated Bass

Creda T622CW Tumble Dryer has no heat, just cold air coming out [ 2 Answers ]

Can anyone offer any advice please? My Creda T622CW Tumble Dryer works fine it just doesn't dry my clothes! Have checked all the filters etc and they are all fine. It has been working OK but seems to just blow out cold air. Is there anything I can do? Or do I need to buy a new one? Thanks in...

Central Air will blow air, but fan outside isn't working [ 3 Answers ]

We have central air, and recently it wasn't blowing cool air like it used to. We then noticed that the fan outside wasn't working even when the central air was turned on. Does anyone know what I should do before calling someone?

Can't get furnace to blow hot/cold air! [ 4 Answers ]

:confused: I recently moved into a house & I can barely tell that any air is coming out. I have just paid to have all the ducts cleaned. Please help me figure this out.


View more questions Search