    Shower Drain
    I am replacing a tub with a shower on a slab floor. I have cut the slab to allow repositioning the drain to the center of the 34 x 60 inch shower, but am reluctant to cut in the other direction to replace the existing 1 1/2 inch drain with the code-required 2 inch drain (the former tub drain cuts into the toilet drain in some fashion, 17 inches away). Rather than cutting the slab back to the wall with the risk of breaking underground plumbing, I would like to use the existing 1 1/2 inch tub drain for the shower. The supply to the shower will be a standard, mixing shower head with 1/2 inch supply.

    Will I have any problems with drainage, or am I good to go?

    Thanks,
    Karl
    Attached Images
     
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Jan 4, 2006, 01:47 PM
    Hi Karl,

    While we like to recommend 2" on our drains, back in the days that I broke into plumbing everything was 1 1/2" galvanized and they're still working. The inspector might not like this but I say , use the 1 1/2" tub drain and good luck. Tom
    silverseal's Avatar
    silverseal Posts: 4, Reputation: 1
    New Member
     
    #3

    Jan 7, 2006, 05:04 PM
    Thanks!
    Tom,

    Thanks for the quick reply.

    I have since rotary-hammered the concrete all the way back to the wall in order to reach the fitting and replace it (photo). Too hard! The existing sanitary tee for the tub drain is tight up against the tee for the toilet which is immediately below. I would have to replace the toilet drain as well and there's no room to work without another day (or more) of chiseling concrete out from under and around the vent. "Fegettaboutit!"

    As I see it, I have two options: 1) go with a inch and a half shower drain as you suggest at risk of some subsequent inspector (not an immediate concern ;) telling me to do it over, or 2) install a 2 inch shower drain and employ a 2 x 1 1/2 reducer to connect to the existing 1 1/2 inch drain (using a high grade marine putty to "fare" the inside of the adaptor to ensure there is nothing to snag on). Option 2 would give the appearance of a two inch drain...

    Which would you recommend?

    Karl
    Attached Images
     
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Jan 8, 2006, 07:25 AM
    Good morning Karl,
    You've talked about inspectors but you've never told me if there was a permit pulled and if you'll be inspected. Inspectors are master plumbers, he's going to snap right away that you've choked the 2" shower drain down to 1 1/2"
    Inspectors have a habit of getting downright persnickity if they think you're attempting a "end run" around code. Are you or are you not permitted? My answer will depend on your reply. Tom
    silverseal's Avatar
    silverseal Posts: 4, Reputation: 1
    New Member
     
    #5

    Jan 10, 2006, 07:11 AM
    Shower Drain
    Tom,

    Not permitted.

    Thanks,
    Karl
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #6

    Jan 10, 2006, 07:28 AM
    Karl, go with the 1 1/2" line and good luck. Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Shower leaking (shower drain pipe?) [ 2 Answers ]

Hi, I will apologize up front for my lack of knowledge in plumbing... but I know enough that I believe that I can fix this problem without having to add on the expense of calling a plumber. I noticed that there were a lot of ants coming into our bathroom. After laying traps and having no...

Shower Drain [ 2 Answers ]

I have a tile shower which has a cracked floor that goes through the tile. I need to get the floor drain out and raised up so I can retile over the existing tile. There are no screws on top or inside the drain. Can someone give me some instructions on how to get this drain loose/removed/raised?...

Rebuilding Shower - Leveling new shower drain? [ 5 Answers ]

Hello, I have come to the postings to get some help as I am a novice plumber. I've gutted my ensuite tilled shower down to the floor. In whacking out the cement pan, and I assumed that I've probably cracked the old drain so when I got to the wood floor I cut away the older PVC 2" piping back...

Leaking of drain from shower drain [ 3 Answers ]

I noticed that my shower drain was leaking under house. I don't know much about plumbing but want to know what could cause this and how it can be fixed. Thanks

Converting cast iron floor drain to shower drain [ 3 Answers ]

I am adding a bathroom to my basement, which has partial (complete? ) plumbing already roughed into the floor (in 1976). Sewage lift station (vented) is 3 ft from 4" styrofoam plug (toilet), 4 ft from 1 1/2 inch cast male pipe end extending through floor (lav, have already added vertical vent...


View more questions Search