    Gas Fireplace Pilotlight
    The pilotlight goes out after I light it, what could be the problem?
    John
    Harvey1955's Avatar
    Harvey1955 Posts: 38, Reputation: 3
    Junior Member
     
    #2

    Oct 17, 2007, 04:31 PM
    Sounds like a bad thermo coupling to me

    . The sticky at the top of h/ac page has lots of info with pictures good luck
    Bluemm's Avatar
    Bluemm Posts: 13, Reputation: 3
    New Member
     
    #3

    Oct 17, 2007, 04:45 PM
    Quote Originally Posted by John Weber
    The pilotlight goes out after i light it, what could be the problem?
    John
    It is probably either a bad thermocouple, or you are not holding the pilot button in long enough after lighting. Usually you have to hold it for 30-45 seconds.
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #4

    Oct 17, 2007, 06:29 PM
    If you don't have a strong pilot flame that is hitting the termocouple a new thermocouple will not do you any good. You will need to clean the pilot assembly a lot of dust will settle down inside it blocking the flow of gas.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Gas Piping Question about gas fireplace [ 5 Answers ]

Hello all, I'm not sure whether to ask this question in the heating forum or here, but it seems to be more a piping question. I am installing a gas fireplace. I got it used, and pieced it together from two sources, meaning I'm needing to change a few things. The burner I got was configured...

Gas Fireplace [ 3 Answers ]

I have a gas/electic ventless fireplace in one of my rental units that is working fine for the first 20-30 minutes... but then it goes out. The pilot light has to be lit again before it will turn back on. The home is 7 years old and the fireplace was installed during construction. Any ideas on what...

Gas line to a gas fireplace [ 1 Answers ]

I have an existing gas fireplace place in my home that I moved 1'0" to the right. There is a copper tubing with a shut off and then flex tubing connecting to the fireplace. I am trying to add additional copper tubing on to the existing so I can extend everything to reach the new location for the...

Gas Fireplace [ 5 Answers ]

Hi, I just bought a ventless propane gas log set. I, however, only have natural gas in my household. Is there a way I can convert the propane set to natural gas? Thank you