    header wall
    I knocked out a piece of wall under my cabinate and think I need a header my opening is 6 ft. wide and approx 2 and a half tall I am opening up a wall to make a bigger counter anyway I have 2 2x4 studs that need to be took out and I am afraid of just taking them out as this was an outside wall at one time there is now a dining room attached and the wall to the dining room is the one I removed part of. Anyway any advice would be helpful.
    Flying Blue Eagle's Avatar
    Flying Blue Eagle Posts: 2,056, Reputation: 225
    Ultra Member
     
    #2

    Sep 11, 2007, 08:21 PM
    THE outside wall was and is a weight bearing eall . If I were you I would most surely would put adouble 2x8 with 1/2" plywood gluded both sides and nailed from both sides with 16 penny coated nails .:":" make sure that the header is suported on each end.
    kathydabarber's Avatar
    kathydabarber Posts: 5, Reputation: 1
    New Member
     
    #3

    Sep 12, 2007, 07:54 AM
    Thank you flying blue eagle,
    another question should I cut the end supports and wedge the 2X8 header in this, is that a possibility? I don't have much room I can support 1 end with a couple 2X4's never mind I think I can support both ends with a couple I would just have to box in the 1 end which will be a collum anyway I was trying not to have too much stick out on the one end and the 2x4 that is there is perfect and on the one side I have a wall full of cabinates I can't take down so I need to attach this from the one side? Am I making sense? Any help out there??
    glavine's Avatar
    glavine Posts: 895, Reputation: 87
    Senior Member
     
    #4

    Sep 12, 2007, 05:00 PM
    If you have an opening of 6ft, which is 72" this what you need to cut your header, now under this header is where you will install the jack studs. once you have the header installed and nailed into place. add the jacks studs or cripples underneath the header, 1 at each end and then every 16" on center.

    as far as removing the 2 2x4s you'll mostly be fine to just cut them out of the way, easiest thing to use if you have once is a sawzaw. If not a handsaw or skil saw will work.


    as I read your last post I'm wondering if we both have misunderstood your first question. Do you have a pic of the area your working in? Email me at [email protected] and ill be more than happy to give you all the answers you need, thanks Eric

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Header in Gable End Wall [ 4 Answers ]

I'm looking for some input on headers required in Gable End Walls. I don't have a true header above my livingroom window and am wondering if, since it is a gable end wall, one is required. In the attached pic, the blue rectangle is the rim joist (SINGLE 2x10 - approx. 15' overall length) which...

Running a two-inch vent though an old header [ 2 Answers ]

I have an old 2x2x8 header that has been framed in and is no longer needed to support load. It is hard up against the top plate and cap plate -- no cripples. The framer added another 2x4 underneath as a plate for the new studs underneath the header. My problem is that I have to get a 2" waste...

Laminated beam as header [ 1 Answers ]

What size laminated beam should I use for a 15 ft. span supporting the back wall of a house as well as an extension with a shed roof thank you

Central heating header tank [ 1 Answers ]

Upon restarting the central heating for the winter period the following 2 things have occurred (I don't think they're related) 1) One of the rads only gets hot at the bottom (3/4 inches up the rad) the rad does not want to bleed i.e. no air coming out. 2) AND MORE WORRYING ! - once or twice...


View more questions Search