Ask Experts Questions for FREE Help !
Ask
    ronaldway9's Avatar
    ronaldway9 Posts: 1, Reputation: 1
    New Member
     
    #1

    Sep 7, 2007, 06:49 AM
    Adding toilet to existing rough in
    I am adding a toilet in addition to one that is roughed in so I will have two toilets in the basement when I am done. Do I tie in where the sewer comes in (adding a backflow valve)or can I tie into the existing 3" toilet rough in. Also, I have a middle foundation between the two toilets. Do I go under the foundation or have to cut through the foundation to run the toilet to the other side.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Sep 7, 2007, 09:43 AM
    Are you just adding a toilet or will it be another bathroom group? I would'nt cut the middle foundation unless I was forced to. You haven't mentioned a vent for your toilet. What's your plans for venting it? Regards, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Adding wires to existing box. [ 4 Answers ]

I recently asked a question about adding a ceiling fan where there wasn't previously a fixture and got my question answered. So, I now know what my plan is for wiring it together. My next question might be a stupid one, but I just thought of it and without experimenting or asking, I don't know...

Adding Breakers to Existing Box [ 4 Answers ]

I'm finishing a basement in a large 8 year old home. We've added about 1500 sq feet in the basement and 5-6 new circuits. The breaker box, and a sub panel are full, with several mini breakers. We've been told that as part of the final electrical inspection a "load analysis" will be done....

Basement bath / kitchenette into existing rough-in [ 2 Answers ]

Speedball1 wrote in a different thread: "Let me tell you how a typical basement bathroom group rough in goes down. 4" under the cement from the toilet to the main sewer. 2" from the lavatory to connect to the 4" toilet drain line. From the top of the lavatory stubout tee a vent line will be...

Adding a heater to an existing circuit. [ 3 Answers ]

I want to place a 240V electric base board heater in a room. In the adjacent room I have a conveniently placed electric wall oven by itself on a 50 Amp circuit with 8 gauge wire. The oven is only rated at 30 Amps and the heater at 4.5 amps. So, I want to run wire from the oven to where the...