New Member
|
|
Jul 7, 2007, 06:41 PM
|
|
Dielectric Union Leak
Hello - I've just installed a new hot water tank, and have two leaks. Each leak is at the dielectric unions. The leaks are very slow. I even took the union apart, cleaned the thread, re-applied the teflon tape and put them back together. I have the same slow drip, on both the hot and the cold side.
I cannot imagine that the unions are bad, but it is possible. Has anyone heard of this before and is there something different I need to do with dielectric unions? Is there something special that needs to be applied?
Thank you
Mike
|
|
 |
Ultra Member
|
|
Jul 7, 2007, 06:52 PM
|
|
 Originally Posted by buns1525
Hello - I've just installed a new hot water tank, and have two leaks. Each leak is at the dielectric unions. The leaks are very slow. I even took the union apart, cleaned the thread, re-applied the teflon tape and put them back together. I have the same slow drip, on both the hot and the cold side.
I cannot imagine that the unions are bad, but it is possible. Has anyone heard of this before and is there something different I need to do with dielectric unions? Is there something special that needs to be applied?
Thank you
Mike
Where are they leaking?
At the nipple on the tank?
Or at the rubber washer where the two halves of the union are joined?
|
|
 |
New Member
|
|
Jul 7, 2007, 06:58 PM
|
|
They are leaking at the nipple on the tank. Please let me know if you need any other information.
|
|
 |
Ultra Member
|
|
Jul 7, 2007, 07:01 PM
|
|
 Originally Posted by buns1525
They are leaking at the nipple on the tank. Please let me know if you need any other information.
When you applied the teflon tape, did you wrap it clockwise in the direction the unions spin on?
Wrapping counterclockwise will make the tape spin off as you tighten the unions.
|
|
 |
New Member
|
|
Jul 7, 2007, 07:03 PM
|
|
I did do it clockwise. Both times in fact, and both times they leaked. I wrapped it around twice, do you think I should wrap it three or four? I didn't want to make it too bulky.
Thanks for the quick responses.
|
|
 |
Ultra Member
|
|
Jul 7, 2007, 07:07 PM
|
|
 Originally Posted by buns1525
I did do it clockwise. Both times in fact, and both times they leaked. I wrapped it around twice, do you think I should wrap it three or four? I didn't want to make it too bulky.
Thanks for the quick responses.
Yikes!
Only twice?
Try 6 or 7 times around.
|
|
 |
New Member
|
|
Jul 7, 2007, 07:10 PM
|
|
All right - I'm off. I'll let you know. Thanks much.
|
|
 |
Ultra Member
|
|
Jul 7, 2007, 07:23 PM
|
|
 Originally Posted by buns1525
alright - I'm off. I'll let you know. Thanks much.
Look at it this way; The manufacturers of pipe dope compounds like Laco, Rector Seal or Mega-Loc for example, direct you to completely fill in the threads with their compound. The same applies for teflon tape.
Also, it must be wrapped tightly.
|
|
 |
New Member
|
|
Jul 7, 2007, 09:37 PM
|
|
Well, still crossing my fingers, and I'll be more confident in the morning, but so far so good. Thank you so much for the advise. That is something I can use for all future plumbing projects.
Thank you once again
|
|
 |
New Member
|
|
Jun 7, 2010, 08:17 PM
|
|
Thanks "iamgrowler". We just installed our water heater and had the same problem with our dielectric unions leaking no matter how hard we tightened it. We used teflon tape but only wrapped around twice! Once we saw this post, and rewrapped the threads with 6 layers of teflon tape, the leaks stopped! Thanks for this heavily important tip! Why doesn't it just ever come with instructions? Haha :)
|
|
 |
New Member
|
|
May 5, 2014, 12:06 AM
|
|
I had the same problem. I used the thicker yellow gas PTFE tape, 6 wraps. You know you are getting a good seal as there is a smooth lubricated feel to the resistance to the wrench. Got rid of the problem. The source of the problem is in the rough threads in the tank, very poor quality.
|
|
Question Tools |
Search this Question |
|
|
Check out some similar questions!
Is brass an alternative to dielectric union?!
[ 8 Answers ]
Good morning speedball,
I am very clear on the theory of electrolysis and such between dissimiliar metals in solutions. But I have read that one can use brass fittings in leiu of a dielectric device. I find that hard to be true. Brass may have properties which can slightly negate the battery...
Dielectric Unions - Necessary?
[ 11 Answers ]
I have searched this site and others to find information on whether Dielectric Unions are really necessary when joining copper and galvanized pipes. The problem; I have found conflicting advice.
In my own case I decided to use them after replacing galvanized for copper at the lav. But both leaked...
Speedball1 >> Dielectric union question
[ 4 Answers ]
Have connected a galvanized 3/4" water pipe to a copper fitting inside a wall and wondered how important is it that these are separated by a brass type fitting or union? OK to use a union inside an outside wall?
Thanks,
Flickit
Connection for dielectric nipple
[ 1 Answers ]
Which way is the best to connect copper to galvenize pipe... gal pipe to brass valve to dielectric nipple to copper..? Thank
Union and non-Union works
[ 2 Answers ]
What are the advantages and disadvantages of Union and non-union works in a Tool and Die industry? :confused:
View more questions
Search
|