    Plumbing a pool cabana
    I have a small pool cabana that sits on the ground i.e. it is not sitting on footings that go below the frost line. I would like to add a bathroom to this building, but am concerned that frost related movement of the structure will damage the plumbing e.g. the toilet flange is fixed to the floor and might snap if the building moves, will the copper joints be loosened etc. There must be a solution for this since mobile homes have the same issue don't they? How do I solve this problem?

    Thanks
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #2

    Jun 6, 2007, 11:21 AM
    A mobile home has a flexible coupling that connects to a PVC drain beneath the home. They also have a furnace which you don't have. How do you plan to prevent the water pipes and toilet from freezing in the winter, no furnace in the cabanna.
    naples's Avatar
    naples Posts: 7, Reputation: 1
    New Member
     
    #3

    Jun 6, 2007, 12:10 PM
    Quote Originally Posted by naples
    I have a small pool cabana that sits on the ground i.e., it is not sitting on footings that go below the frost line. I would like to add a bathroom to this building, but am concerned that frost related movement of the structure will damage the plumbing e.g., the toilet flange is fixed to the floor and might snap if the building moves, will the copper joints be loosened etc. There must be a solution for this since mobile homes have the same issue don't they? How do I solve this problem?

    Thanks
    Thanks. Is this flexible coupling available at most plumbing supply stores? I am going to have blowouts placed in the water lines so that they can be evacuated in the fall. The toilet and sink trap will be filled with potable water antifreeze.
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #4

    Jun 6, 2007, 02:20 PM
    Speedball1 or Iamgrowler can help you better with this item. They should be here later today. I think its just a neopreme collar but not sure.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #5

    Jun 6, 2007, 02:49 PM
    Quote Originally Posted by ballengerb1
    Speedball1 or Iamgrowler can help you better with this item. They should be here later today. I think its just a neopreme collar but not sure.
    You're looking for Fernco Flexible Couplings, (see image). Click on; Fernco, Inc. to check them out. Good luck, Tom
    naples's Avatar
    naples Posts: 7, Reputation: 1
    New Member
     
    #6

    Jun 6, 2007, 05:55 PM
    Thanks for all of your help. I will look into the Fernco connectors.
    iamgrowler's Avatar
    iamgrowler Posts: 1,421, Reputation: 110
    Ultra Member
     
    #7

    Jun 6, 2007, 07:24 PM
    Quote Originally Posted by naples
    Thanks for all of your help. I will look into the Fernco connectors.

    You can also use 'ductile' PVC to plumb the portions below grade.

    I've plumbed a number of house boats where flexibility in the lines below the sub-floor is required -- "Ductile" PVC is soft and flexible enough to move with the building.
    naples's Avatar
    naples Posts: 7, Reputation: 1
    New Member
     
    #8

    Jun 7, 2007, 04:27 AM
    Thanks for the additional information about ductile pvc. I'll look into this as well.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Under above ground pool goes. [ 3 Answers ]

Last year I put up a 15' above-ground pool. I do not have any great level spot in the yard but found an area that worked okay. Unfortunately, it's at the bottom of a slope... so it stays wet easily. This year, I'm wondering what to put under it besides the tarp-thing that came with it. If I made a...

Pool Plumbing [ 5 Answers ]

Hello, I have a pool pipe that goes from my skimmer to pump. It sprang a leak. The pipe was copper about 1.25 inch diameter. The pool company cut off the pipe at the leak (around 1 foot from pump) and fit on a larger diameter PVC pipe with some type of transition coupler over the copper pipe....

Pool, spitters or over pool jets of water [ 1 Answers ]

Can anyone tell me where to find the spitters that send streams of water over the pool. Thanks, Judy

Plumbing sleeves for pool replumbing [ 2 Answers ]

Does anybody know of a product for resleeving 1.5 copper pool pipe? I am repairing a concrete/plaster inground pool built in the late 50's. 1.5 inch copper pipe was used. I know I have a leak on the return line and also believe I have one on the main pool drain (the pool water level drops to...

Garden Pool [ 1 Answers ]

Hello, I recently moved into a house with a 3' x 4' concrete garden pool. It has a spout in the middle of the pool and city water can be turned on with an old-fashion T device. There is also a built-in overflow valve. A plumber advised me that I should not use city water, because it would cost...


View more questions Search