    Replacing lead with PVC
    I am remodeling a commercial building that's about 80 years old. The plumbing inspector says that the lead pipes connecting the toilet, bathroom sink, and kitchen sink to an iron tee must be replaced with PVC. This is in an apartment. It does not leak and functions correctly.

    Since it is in concrete it is going to be a lot of work to take it out, put in PVC, and redo the subflooring.

    Where in the Plumber's codebook does it say I have to replace this? I know electricians use the NEC 2005 book - what code book do plumbers use? I am in the state of Ohio.
    Attached Images
     
    iamgrowler's Avatar
    iamgrowler Posts: 1,421, Reputation: 110
    Ultra Member
     
    #2

    Apr 26, 2007, 07:55 PM
    Quote Originally Posted by Ohio_Remodeler
    I am remodeling a commercial building that's about 80 years old. The plumbing inspector says that the lead pipes connecting the toilet, bathroom sink, and kitchen sink to an iron tee must be replaced with PVC. This is in an apartment. It does not leak and functions correctly.

    Since it is in concrete it is going to be a lot of work to take it out, put in PVC, and redo the subflooring.

    Where in the Plumber's codebook does it say I have to replace this? I know electricians use the NEC 2005 book - what code book do plumbers use? I am in the state of Ohio.
    This is a judgement call by the inspector, likely made when he saw that the trap arm for the tub had been modified.

    There is no accepted transition from lead to PVC, because the only acceptable lead joint is a wiped joint, which requires heat in excess of the PVC pipes rating.

    I hate to break it to you, but Plumbing Inspectors have broad discretionary authority, which means 'Because I Said So' is more than enough reason to fail an inspection.

    Bringing this abortion up to code may end up being costly pain in the tukas for you, but you need to remember that the Inspector also needs to be able to sleep at night, and signing something like this off would keep me awake for a very long time.
    Ohio_Remodeler's Avatar
    Ohio_Remodeler Posts: 85, Reputation: 1
    Junior Member
     
    #3

    Apr 26, 2007, 10:02 PM
    Thanks for the response. Looks like I've got some work to do.
    iamgrowler's Avatar
    iamgrowler Posts: 1,421, Reputation: 110
    Ultra Member
     
    #4

    Apr 27, 2007, 06:51 AM
    The inspector would have likely overlooked this portion of the system if it hadn't been modified -- Although there has been a push in the field over the past five or six years to dis-allow the grandfathering in of systems that are blatently not in compliance with the prevailing adopted Plumbing Code.

    It might be worth your while to pay a Plumber familiar with the expectations of your local Plumbing Inspectors to come out and give the job a once over before calling for re-inspection.

    Just a thought.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #5

    Apr 28, 2007, 07:16 AM
    I am no fan of lead plumbing, however I am a big fan of, "If it ain't broke don't fix it."
    Having said that Growlers suggestion to hire a plumber to check your job and advise you is top notch. Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Replacing a brass closet flange on a lead pipe [ 3 Answers ]

Okay, so I'm renovating my bathroom and running into some issues with the old plumbing. Here is a link to some pictures of the situation which will do a much better job at describing things than I can. Picasa Web Albums - Jonathan - plumbing Obviously the ideal situation would be to...

Connecting pvc to pvc with no hub fitting [ 8 Answers ]

My plumber ran into a dilemma when installing rough plumbing for a new basement bathroom. After already laying the pvc piping in place under the broken up concrete floor we found the pvc to cast iron Tee connections leaking. This was discovered after I had filled the opening with a base of gravel...

How thick is the lead in a lead joint [ 2 Answers ]

Im getting ready to take the Indiana pluming test and I was wanting to know how thick the lead Is suppose to be in the hub of the cast iron.

Replacing a toilet flange with a lead connection [ 6 Answers ]

I am about to pull up my old toilet and take a close look at what's underneath. I am also going to go over the original plank sub-floor with fresh 3/8" ply (followed later with thin lauan for eventual linoleum) there is a visible floor patch from an old repair. Given the fact that there has been a...

Replacing lead pipe with pvc [ 9 Answers ]

The lead pipe and drain from my father-in-laws' bathroom is leaking and needs to be replaced. I'm tempted to just remove all of the lead (only a few feet) and cast iron all the way to the entry into the main discharge. Currently the 2 pieces of cast iron have a leaded seal. How do I connect...


View more questions Search