    Rheem RGAA Gas Forced Air... can I test it without the gas turned on
    30 year old forced air unit that I want to test to see if it runs and if it can be repaired but the gas service is currently turned of to the property. I have power and I can hear the hum of the 24volt transmitter can I get the fan to run without fuel? Thank you
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #2

    Oct 1, 2015, 03:27 PM
    Furnace should have a HI-lO switch. The Hi-lo switch turns the blower motor on when temperature in the heat chamber reaches a certain level. Turns the blower off when drops. This prevents the fan from blowing cold air while the heat chamber is getting up to temperature.

    You could by pass the Hi-LO switch but would be easier to simply pull the blower and motor out an connect it to a directly to a power source.

    Open lower compartment, you should find the blower assembly on a rail system. Disconnect it electrically. Slide entire assembly out and connect it directly to a power source. Clean every thing while you have it out.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Heater gas forced air [ 1 Answers ]

I have a combo heat and cooling system the problem is with the heat the unit cycles glow light comes on the furnace firers up and then shuts down I have to reset the system two maybe three times what causes this seem like every night I have to go through this what can it be

Dual zone gas heat w/ forced air up is blowing cold air on second floor. [ 1 Answers ]

We have a gas furnace with two thermostats and forced air on the second floor. The heat works fin everywhere but the second floor. The temperature is dropping and the registers have cold air blowing out of them. Any suggestions on what the problem could be?

Forced air gas furnace [ 1 Answers ]

I have a Rheem forced air gas furnace. The pilot will light manually and will run properly for a while, but it cuts off before reaching temperature and the pilot goes out. I've relit it several times, but it keeps doing the same thing. Any suggestions?

How efficient is it to convert gas forced air to electric forced air? [ 1 Answers ]

I am afraid of a gas furnace, for fear of an explosion. I have had this fear since I was a little boy. Hence, I simply must have an electric heating system. However, the area in the MidWest where I have been considering has almost no electric homes, mostly because of the high electric rates...

Gas Forced Air vs. Boiler [ 1 Answers ]

I think I'm a little off the wall here since I haven't seen this question asked this way anywhere else, but here goes: Would anyone ever recommend replacing an existing gas/forced air heating system with a gas boiler and radiators for hydronic heat? I know that all things equal, I would...


View more questions Search