    Removed old hot water tank problem
    Hey all, I am just a 2nd year apprentice plumber and I decided to remove my old and now leaking Hot Water Tank (leaking from inside above the gas burner). I decided to cut out and remove the old tank today and will get and install the new one tomorrow. That said, all the water pressure throughout the house is normal (for cold) except for both showers, which have mixing valves. The cold water pressure is very, very low. Did I do something wrong or is this just the nature of things? Thanks!
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Jul 20, 2015, 05:07 AM
    Hi RC

    All shower valves have been temperature and pressure balanced for decades now. Basically, this means that a shower valve will "balance" the temperature of the water according to the VOLUME of water being fed into the valve. In your case, since you have no hot water feeding into the shower valve, you will see a corresponding drop in cold water volume/pressure just like you described.

    Once you install the water heater and purge the lines your shower valves should be up and working properly again!

    Good luck!

    Mark

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Had no hot water but had cold water... defrosted pipe from main to hot water tank. I [ 4 Answers ]

Very cold in Ohio... 25 below... had cold water but no hot water... defrosted hot water line from attic to tank... have hot water in kitchen but no hot water in bathroom. Have the shower valve for hot water open and when I turn on the cold water in the hand sink, water comes out of the faucet in...

Header tank filling to overflow through the cold water feed pipe to hot water tank [ 0 Answers ]

My cold water tank is overflowing and after turning the water off the water seems to be coming up through the cold water pipe from the hot water tank, any idea as to what could be causing this to happen?

Problem with new hot water tank [ 1 Answers ]

We recently installed a new water tank as old one had a leak. Only problem is hot water is a disgusting brown. We have drained tank several times but so far no joy. Any suggestions?

Replaced a hot water tank,water is not going to the pressure tank-the pump stays on [ 2 Answers ]

Replaced a hot water tank, turned the pump on and the water is bypassing the pressure tank. The pressure tank will not fill up and the pump remains on and will not shut off. We do get water though but needs to shut off the pump so it will not burn out. Any thoughts? Thank you Any ideas will...


View more questions Search