    PEX to Polyethylene connection
    I'd like to install a frost free hydrant in my backyard 250ft from my house. My plan is to run 1" polyethylene pipe 4' underground from my basement (through the foundation) to the hydrant. I have a manabloc water manifold with 1/2" PEX pipe. Is there a way to connect the 1" black polyethylene to the 1/2" PEX inside my basement or will that limit my water pressure in the 1" pipe? Is there another solution other than connecting to the 3/4" PVC pipe connecting my well pump to my water manifold and hot water heater?
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Jul 18, 2015, 09:09 PM
    The issue isn't as much PRESSURE, but more so WATER VOLUME. Here, attaching a 1" pipe to a 1/2" pipe will reduce the volume of water available in terms gallons per minute to that 1" tubing. The distance you mention further aggravates things. Attach your 1" tubing to the 3/4" PVC pipe as that seems the best you can do here. Pressure will be pretty stable and volume (GPM) will be much greater than attaching to the 1/2" manifold.

    Mark

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

5/8 in. pex vs. 1/2 in. pex installed in cement heated floor [ 0 Answers ]

What are the advantages of using 5/8 in. pex in floor heated cement over 1/2 in. pex ?

Regular Pex with wirsbo pex pipe [ 1 Answers ]

Can someone please let me know if you have to use Wirsbo fittings with Uponor pex a tubing? Thanks Joe

Polyethylene high Coefficient of Friction's [ 0 Answers ]

I am looking for a material that has a high coefficient of friction against Polyethylene (LLDPE I believe) Additionally if anyone could provide a LLDPE vs other materials COF chart that would be greatly appreciated! Thanks!

1/2'' copper down to PEX - which size PEX is best? [ 1 Answers ]

We're finishing our basement and I want to re-run the kitchen supply line because the 1/2'' copper runs underneath (perpendicular) to the 16'' on center joists and thus lowers the ceiling by a full inch (it will need to be shimmed). I want to install PEX that runs through the center of the joists...

Polyethylene [ 2 Answers ]

Hi,I need some information about impact test on Polyethylene ( gas distribution Pipeline) ?where can I find some useful information.Thank you


View more questions Search