    Modad or toilet issue?
    Moved here 3 years ago. Not sure if the 3-compartment modad was new but the aerator was new. I had no prior experience with modad/septic systems. Company that installed the aerator came out several times because the alarm kept going off. They told me someone put in sanitary napkins and mop strings which I was shown but was absolutely not possible by me (unknown if I had enemies or how it got there). Since that was finally fixed about a year and half ago I did not have problems until...

    Several months back I noticed the system was not running and when the reset button was pressed it kicked on and right back off. It didn't seem as if anything else was malfunctioning so I thought maybe it worked on some kind of timing thing.

    Now one of my toilets (one that is used most) when flushed, started filling up to the rim near overflowing and going down slowly and then the water doesn't rise back up much. It got to where it seemed the water was getting slower going down so I had stopped using that toilet until I could ask someone and work on getting it fixed. It has been burping especially when I'm running the washing machine. And it seems that my shower drain may be filling quicker than usual; has puddle at start of shower. It's now about 3 weeks later since not using that toilet and I see a bunch of small, black bugs (I think) and possibly fluttering.

    1. Am I looking at more than one issue?
    2. Where should I start?
    3. Once corrected what do I need to know so as not to cause problems myself?

    I just read that I should have been using some kind of rid-x once a month yet some folks have had problems with it forming bugs. Also read that I should limit amount of laundry per day... had no idea.

    4. It's only me so could I really be using too much water? I can't imagine what a family with kids would do.

    Thanks for any advice provided!
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #2

    May 26, 2014, 01:12 PM
    If only 1 toilet is backing up, it is most likely not a part of the Modad issue. I will assume you are in the Delta area, MS-LA etc. Burping is typically indicative of vent issues, a plugged vent and the system is trying to vent through the drain. Have a plumber clean all the drain and vent lines. Drain flies, small black flies, are associated with slow draining issues as their eggs must stay wet. They are a real pain to get rid of. I had them in a shower drain and it took quite a while to kill the flies and larva.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Modad septic system [ 2 Answers ]

Why is buzzer alarm and red light on? How do we fix it?

Modad septic operation [ 3 Answers ]

Just wondering about our modad system. We just moved to Louisiana and the house we bought has such a system. It has recently been checked by the county and all seems to be working well. We aren't having any problems with it but I don't know much about the system. I was wondering if we need to...

Modad Septic System [ 2 Answers ]

My house has a MoDad system and I was told I must use an aerobic bacterium every month. Is this not correct?

Modad Septic Tanks? [ 0 Answers ]

Why dose a smell come from the septic tank in to the house

Prices of a Modad [ 1 Answers ]

I have to put down a modad on the property I just bought and need to compare prices. Can I find the price of a modad online?


View more questions Search