    Water well priming
    I have an ao smith water well pump model #c48l2n134c2. I lost power to the pump for about 2 hours and now my pump is running but my psi gauge reads 9 and I have no water. Has it lost it's prime?

    My psi gauge on my pump reads 0 after losing power for about 2 hours, do I need to prime it and if so how do I do that?

    How do I prime an A.O. Smith model# C48L2N134C2 water well pump?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Apr 12, 2014, 05:20 AM
    This is a surface pump is that correct? On top of the impeller cage they should be a plug or a pressure gauge that you can remove and fill the impeller cage with water. Replace the plug or the gauge and turn the pump back on. Good luck Tom

    pump reads 0 after losing power for about 2 hours
    It sounds like a faulty foot/check valve to me. Try priming the pump again and if it loses water check and replace the valve. Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Deep well priming not getting water pressure [ 3 Answers ]

I have prime my deep well pump, several times water seems that it is getting into the line but it is not holding pressure at all. The pump is running and only holding at 10 and not at 30 as it should. I have tried everything that I can think of and I am at my end of my rope. Any answers please...

Priming water pumps [ 3 Answers ]

How can I prime my home water pump? It is similar to a swimming pool pump.

Priming a burks water pump [ 1 Answers ]

I would to know how I prime my water pump. It's a Burk brand pump.

Priming an above ground water pump [ 2 Answers ]

The water in my shallow well went below the pipe last summer and my pump needs priming. When I turn it on it has pressure in the tank but no water. How do I prime this above ground water pump?