New Member
|
|
Feb 4, 2014, 06:48 AM
|
|
Low water pressure caused by a check valve? Please help.
I live in NY. Ground is frozen. Just diagnosed that I have leak in my water line or well pump between the house and the well. It's a submersible well brand new 55 feet in well and 60 feet from house. I was getting hammering in line and shaking. I just cut line in basement and installed a check valve, and no more hammering or shaking. And holds good pressure now. But I have very low pressure in cottage now. Any ideas why? Only other thing I added was a union between the brass t and pressure tank for easy connect.
|
|
 |
Uber Member
|
|
Feb 4, 2014, 04:25 PM
|
|
Just to be sure (after reading your previous posts under a different thread), you did install the CV between the pump and tank, and not between the tank and the house? As I understood, this was going to be a temporary measure to overcome a leaking pipe until the ground thawed.
When you say you have low pressure in the cottage, do you mean from faucets? If so, have you cleaned the aerators?
|
|
 |
New Member
|
|
Feb 4, 2014, 04:32 PM
|
|
Thanks for responding. Yes the CV is in the basement as it enters the wall but is about 4-5 feet from the pressure tank. I almost have normal pressure in the shower now. But just drips in the kitchen sink small trickle hot and cold, but if I use the spray nozzle there is OK pressure in that. The hot water in the shower is almost normal, and the cold only about half pressure of what the hot is.
|
|
 |
New Member
|
|
Feb 4, 2014, 04:45 PM
|
|
And yes. I took the aerator off and same water pressure without it on there. Its only 2 weeks old.
|
|
 |
Home Improvement & Construction Expert
|
|
Feb 4, 2014, 08:19 PM
|
|
What kind of piping do you have where you installed the check valve?
|
|
 |
New Member
|
|
Feb 4, 2014, 08:32 PM
|
|
Black 3/4" poly
|
|
 |
Home Improvement & Construction Expert
|
|
Feb 4, 2014, 08:43 PM
|
|
Is it possible that you got some bits of piping in the line as you cut the line to installed the check valve?
Water pressure will be the same hot and cold at all faucets. Only logical explanation is that there is some debris in either the stop valves or the faucet. Debris would move to the first faucets used. Since hot and cold are blocked most likely faucet. Remove kitchen stems, hot and cold if two handle, remove cartridge or ball is single handle. Inspect and clean. Briefly turn on water to flush pipes.
|
|
 |
Uber Member
|
|
Feb 5, 2014, 07:18 PM
|
|
I almost have normal pressure in the shower now. But just drips in the kitchen sink small trickle hot and cold, but if I use the spray nozzle there is OK pressure in that. The hot water in the shower is almost normal, and the cold only about half pressure of what the hot is.
Sure seems to back up HK's theory.
|
|
 |
New Member
|
|
Feb 5, 2014, 07:30 PM
|
|
I removed lines from kitchen sink and put the ends in a gallon jug and I have tons of water and pressure when I turn on the ball valve. So I have debree in the faucet somewhere. Thanks all.
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Very low hot water pressure, moen 1 handle shower valve
[ 13 Answers ]
I have a moen 1 handel shower valve. When I turn it on I have good cold pressure but hardly any hot pressure. I removed handle and turned stem all the way to hot but still I have low pressure. I tried to adjust scald guard but that is not the problem is there any other adjustment?
Low Water Pressure caused by softener
[ 3 Answers ]
Hi, I've been having low water pressure issues in the house for the last couple weeks so I had a guy come out today to look at my system. He put the water softener in bypass and the pressure increased to normal. He automatically said I need to purchase a new water softener which are basically 700...
Why do I have low Water Pressure after diassembling diverter valve?
[ 4 Answers ]
I disassembled diverter valve from Sprayer and Faucet (I wouldn't have had to from faucet) so that I could put a new holder for the sprayer on the sink. No other parts are new. And now I have low water pressure from both hot and cold. Should the diverter valve be replaced?
Low water pressure after turing main valve back on
[ 1 Answers ]
I needed to turn the main water valve to the house off for a plumbing repair. Made the repair, turned the main valve back on and there is very little water pressure throughout the house. How do I restore the water back to the original water pressure?
View more questions
Search
|