Ask Experts Questions for FREE Help !
Ask
    kchrist's Avatar
    kchrist Posts: 1, Reputation: 1
    New Member
     
    #1

    Apr 7, 2007, 12:48 AM
    Pipe noise - not water hammer
    Copper pipe "thump" noise occurs intermittently (approx. every 20 seconds) and diminishes after approx. 2 hours following shutoff of hot water tap in kitchen. The noise is not location specific and is loud for the first hour and a bit. The noise resembles the sound you hear when pipes are expanding or contracting but is much louder at first. After approx. 2 hours, the noise can only be heard every 40 seconds or so then stops. My house was built in 1957 and only recently started making this sound. I'm convinced it is not water hammer yet have not been able to determine what it is through resources on the internet. Suggestions?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Apr 7, 2007, 06:58 AM
    Water hammer occurs when you shut off a faucet so I agree it's not water hammer. Sounds more like expansion and contraction. Knocking, popping, creaking and crackling pipes are a common complaint, especially in colder weather. I can tell you what's happening and take the mystery out of it but you're not going to like the repair. When a draw is made on a hot water line the line expands against a pipe strap next to a stud and when you drain hot water from your tub or shower it goes into a chase that is a little cooler then room temperature. The heat expands the pipe causing it to rub against the stud to which it is pipe strapped. This is the sound you hear. As it cools it contracts and the noise is heard again. To repair it you must tear open the walls and locate the pipe strap that's causing the problem and shim it tight. Most people when they learn what causes it just elect to live with it. Regards, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Water Hammer from the Well Pump [ 10 Answers ]

Since installation I have had water hammer when the pump shuts off. The installer "never saw this happen before". The 3/4 hp 8 gpm pump is 140 feet deep, and the well is about 400 feet (horizontal) from the house. The supply line is 1" Kitek. The supply couples into a brass 90, makes a copper...

Hot Water causes copper pipe noise [ 10 Answers ]

Recently, we replaced the old galvanized pipe in out home with copper. When the hot-water is turned on in the tub we get a popping/banging sound that is most intense for the first minute or so that the water is running. The intensity of the noise decreases but continues for about 10-15 minutes...

Hammer in pipe after renovation [ 3 Answers ]

Hi there. I recently had both of my bathrooms renovated and noticed that after you flush either commode there would be a loud thump that was felt in the wall of the great room after the commode tank was finished refilling and the water shut off. The contractors were still working, and before they...

Water Hammer [ 1 Answers ]

I have what appears to be water hammer in a 18 yr old home. Water arrestors (the blue oil can) are installed. From what I've read, it seems like the solution is to remove the air from the water lines starting with shutting off the main water valve, then draining the pipes. If this is true, then...

Pipe banging other than water hammer? [ 3 Answers ]

Hi there, Recently the pipes in our house have started banging. My initial thoughts were loosely hanging pipes or water hammer. I secured the pipes better/tighter with hangers, but the problem continues. Water hammer would be a possible idea, except it only seems to happen from the toilet pipes...


View more questions Search