Ask Experts Questions for FREE Help !
Ask
    harum's Avatar
    harum Posts: 339, Reputation: 27
    Full Member
     
    #1

    Sep 12, 2013, 03:47 PM
    Compression fittings
    Hello, how many turns past hand tight should I tighten stainless steel compression fittings at the ends of those yellow flexible gas connectors for gas range or dryer? I can only put an extra 1/5 turn past hand tight, which is quite different from regular black pipe fittings. Any input would be appreciated. Thanks, h.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Sep 12, 2013, 03:51 PM
    Hi Harum

    You tighten those nuts using two wrenches or pairs of pliers to as tight as is reasonable... 1/5th turn doesn't sound far off here! Remember that you do NOT use pipe dope on the nuts in question... just use pipe dope on the pipe threads, not the connector threads, OK? When you turn the gas on take a soapy bubble solution and test the joints to confirm all is good.

    If you are installing a stove, please be sure to install the anti.-tip device as this device saves lives... ;)

    Mark
    Attached Images
       
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #3

    Sep 12, 2013, 04:04 PM
    Pipe threads are interference fit, slightly coned shape, so it does take a fair amount of wrench twisting. However, those fittings on the yellow pipes are NOT compression fittings, they are FLARE fittings, compression fittings are not allowed on gas lines, only iron pipe and flare. Easy to confuse but I have seen people ask for compression and put them on a gas line.
    harum's Avatar
    harum Posts: 339, Reputation: 27
    Full Member
     
    #4

    Sep 12, 2013, 05:09 PM
    Quote Originally Posted by ma0641 View Post
    Pipe threads are interference fit, slightly coned shape, so it does take a fair amount of wrench twisting. However, those fittings on the yellow pipes are NOT compression fittings, they are FLARE fittings, compression fittings are not allowed on gas lines, only iron pipe and flare. Easy to confuse but I have seen people ask for compression and put them on a gas line.
    Yes, you are right. Sorry, I meant flare fittings, the kind on the last photo posted kindly by Mark above. I have carefully read the provided info and, of course, don't use any pipe on those connections. Nothing said about what I am asking. But still, looks like a fraction of a turn past hand tight should do?
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #5

    Sep 12, 2013, 05:18 PM
    Quote Originally Posted by harum View Post
    Yes, you are right. Sorry, I meant flare fittings, the kind on the last photo posted kindly by Mark above. I have carefully read the provided info and, of course, don't use any pipe on those connections. Nothing said about what I am asking. But still, looks like a fraction of a turn past hand tight should do?
    Yes, tighten hard but don't distort. I don't think Mark agrees with this, but I always put a VERY thin Teflon pipe thread smear on both mating surfaces, not the flare threads. Check with soap solution. I get a bubble solution at Dollar Tree and use with a small brush. Lasts almost a year for me. Fortunately the odorant usually gives a leak away.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search


Check out some similar questions!

Plastic compression fittings how to [ 3 Answers ]

Which is the proper orientation for a plastic compression ring? Large end towards the outlet pipe or into the compression nut?

Copper plumbing compression fittings [ 5 Answers ]

How do I reconnect 1/2"opper tubing that has been cut?

Copper plumbing compression fittings [ 1 Answers ]

How do I connect !/2" copper pipe (straight line) that has been cut? With compresssion fittings?

Compression fittings not in far enough [ 1 Answers ]

I just fixed my old dishwasher line and I had to cut out a leak. I had enough copper tubing to just reroute the remaining tubing into the valve stop. However, it is an older house and the outside diameter of the tubing was a bit wider than what we use now. I got the nut on as far as I could and...


View more questions Search