    Adding a new toilet\shower in a detached garage
    Hello, I am new to the forum and have enjoyed reading all the valuable knowledge people sharing here. I am planning to build a detached garage about 24' from the house and about 35' to the vertical drainage pipe locates in the bottom of the tri-level in which is about 5' deep from the surface. I assume to add the normal 2' to 4' below that to find the actual pipe. The vertical pipe is 4' size. My plan is to install a new toilet and shower in the garage for which should tie in with the existing drainage from the house. I plan to use the 1/4" pitch per foot formular.

    My questions:
    1) what material do I use from the garage to run the drainage system?
    2) Can the new shower pipe share with the toilet one?
    3) What do I need to use to connect to the one from the house?
    4) Does a plumber just cut a hole to the cast iron pipe from the house and insert a new one for the connection?

    Thanks in advance,
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Mar 31, 2007, 06:07 AM
    1) what material do I use from the garage to run the drainage system?
    I would go for PVC.
    2) Can the new shower pipe share with the toilet one?
    If you're asking if the shower can connect to the toilet drain the answer's yes. However the shower will have to be vented.
    3) What do I need to use to connect to the one from the house?
    You will have to cut in a 4 X 3" combination wye and eighth bend In the vertical pipe and run from there to the garage.
    4) Does a plumber just cut a hole to the cast iron pipe from the house and insert a new one for the connection?
    No, he cuts in a fitting, (answered in #3.)
    more questions? I'm as close as a click. Tom
    yip88's Avatar
    yip88 Posts: 7, Reputation: 1
    New Member
     
    #3

    Apr 2, 2007, 09:49 AM
    Quote Originally Posted by yip88
    Hello, I am new to the forum and have enjoyed reading all the valuable knowledge people sharing here. I am planning to build a detached garage about 24' from the house and about 35' to the vertical drainage pipe locates in the bottom of the tri-level in which is about 5' deep from the surface. I assume to add the normal 2' to 4' below that to find the actual pipe. The vertical pipe is 4' size. My plan is to install a new toilet and shower in the garage for which should tie in with the existing drainage from the house. I plan to use the 1/4" pitch per foot formular.

    My questions:
    1) what material do I use from the garage to run the drainage system?
    2) Can the new shower pipe share with the toilet one?
    3) What do I need to use to connect to the one from the house?
    4) Does a plumber just cut a hole to the cast iron pipe from the house and insert a new one for the connection?

    Thanks in advance,
    Hi Tom,
    I found another drainage pipe under crawlspace which I believe the washer and the dishmachine use. I don't think they are as wide as the vertical one which connects to the City main sewer. Can I connect the garage (toilet or shower) to it? If I can, what do I need to be concerned of? Thanks in advance,
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Apr 2, 2007, 10:36 AM
    Hi Tom,
    I found another drainage pipe under crawlspace which I believe the washer and the dishmachine use. I don't think they are as wide as the vertical one which connects to the City main sewer. Can I connect the garage (toilet or shower) to it? If I can, what do I need to be concerned of? Thanks in advance,"

    If the pipe's at least 3" and it runs to the sewer you may connect to it. You will still have to vent the shower. Let me know when you're ready and I'l walk you through the venting part. Regards, Tom
    yip88's Avatar
    yip88 Posts: 7, Reputation: 1
    New Member
     
    #5

    Apr 2, 2007, 03:11 PM
    Now, in either situations, I would need to dig deep enough below the concrete slab to connect either pipes, right? One would be 7' feet down for the veritcal pipe or 3' feet down for the crawlspace drainage. Or should I cut the concrete from above and refill it later. I can use the 3" PVC to connect to the 3" crawlspace pipe, right? Thanks again,
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #6

    Apr 3, 2007, 08:11 AM
    " I can use the 3" PVC to connect to the 3" crawlspace pipe, right?"
    Correct, Let me know what you decide. Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Adding shower and toilet in basement [ 1 Answers ]

I am installing a toilet and a shower stall in the basement need to put drain lines in. Need step by step instruct. Doing it myself.

Detached garage pad [ 2 Answers ]

I am trying to get some information on building a garage starting with the Pad. I am planning on building a 22X26 detached garage. The rough grade was completed about 4 months ago. It is a clay base with no topsoil added yet. Should I get a bobcat in to remove a couple inches or just pack down...

Detached garage grounding rod or not [ 1 Answers ]

Hi, I just ran across another problem. I will be running 40 amps 240 volts out to my garage via underground 8-3 plus ground. Do I need a grounding rod at the garage or is the ground via the service cable to the garage enough? I have seen both and am not sure why. Is the 240 volt service to the...

Detached garage panel install, please help [ 2 Answers ]

Hi, I am running 8-3 underground in pvc conduit and am wondering: 1. How high up the garage wall I should come up before entering the garage (I guess this means how high the panel will be on the inside as well)? Any code for this or is whatever height is comfortable good enough? 2. Also, I...