Ask Experts Questions for FREE Help !
Ask
    Lonitrach's Avatar
    Lonitrach Posts: 3, Reputation: 1
    New Member
     
    #1

    Jun 1, 2013, 05:59 PM
    Floor drain question
    I have a drain in my basement floor. When I am doing laundry sometimes I notice I hear a bubbling sound, however it is not over flowing. I checked on it last time and took the cover off and noticed the water was kind of low (lower than it is normally, and this has happened more than once) and there was a horrible smell filling up the basement. My two questions are is the smell sewer gas leaking in and is it normal to have to fill up the water ever so often? I am a first time female home buyer and have no idea what it could be. Thank you!
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #2

    Jun 1, 2013, 07:51 PM
    Floor drain must have trap. Also, in my area of operation, we are required to install so called "Primer" in each floor drain. Primer is a device that constantly drips water into floor drain disallowing water inside the trap to dry out.

    See the attachment for better visual...

    Purpose of water inside the trap is to prevent sewer gases from entering living space. Smell is product of dry trap. If there is not a Primer installed than make it a habit of filling up the floor drain (trap) every week or so with cup of water. With full trap, sewer gas will be kept inside the sewer pipe.

    Hope that helps. Back to you. Milo
    Attached Images
     
    Lonitrach's Avatar
    Lonitrach Posts: 3, Reputation: 1
    New Member
     
    #3

    Jun 1, 2013, 08:23 PM
    Thank you for your answer. Do you know roughly how much it would cost to have a primer installed?

    Quote Originally Posted by Milo Dolezal View Post
    Floor drain must have trap. Also, in my area of operation, we are required to install so called "Primer" in each floor drain. Primer is a device that constantly drips water into floor drain disallowing water inside the trap to dry out.

    See the attachment for better visual ...

    Purpose of water inside the trap is to prevent sewer gases from entering living space. Smell is product of dry trap. If there is not a Primer installed than make it a habit of filling up the floor drain (trap) every week or so with cup of water. With full trap, sewer gas will be kept inside the sewer pipe.

    Hope that helps. Back to you. Milo




    Thank you for your answer. Do you know roughly how much it would cost to have a primer installed
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #4

    Jun 1, 2013, 09:25 PM
    Unless the drain is installed on raised foundation floor, it would be too big of a job to install one in on a drain set in concrete slab floor. However, yes, it can be done...

    You would need to install "tapped" trap under the drain and run primer line to the closest wall. Then you would have to connect the primer line to cold water supply, install Primer and cover it with access door so Primer can be adjusted and serviced.

    Prices vary widely from city to city and many additional factors will determine how much you can expect to pay for such work. I suggest that you call three plumbing contractors and ask for free estimates. Ask lots of questions. Go with the one you feel most comfortable with.

    Hope that helps. Back to you. Milo
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #5

    Jun 1, 2013, 09:41 PM
    Water would typically evaporate from the trap. You can use a 50/50 mixture of water and Antifreeze or fill the trap and pour a 1/4" of cooking oil on top of the water. Lot cheaper than installing a primer.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #6

    Jun 2, 2013, 06:45 AM
    Easier and cheaper than a trap primer and less trouble than frequently replacing oil in the trap is installing a SURE SEAL trap sealer.

    Check out this video for more info.:



    Check out this link for more info.:

    Sure Seal

    Good luck!

    Mark
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #7

    Jun 2, 2013, 07:22 AM
    If the FD isn't in use simply fill the trap with anti-freeze or cooking oil and forget it. This saves you the expense of breaking up the cement and installing a trap primer. Good luck, Tom
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #8

    Jun 2, 2013, 08:26 AM
    Did you check out the sure seal, Tom (see video above)? This device is pretty cheap, and makes it so that you don't need to periodically check for evaporation or bugs, etc.

    It's what I would use...
    Lonitrach's Avatar
    Lonitrach Posts: 3, Reputation: 1
    New Member
     
    #9

    Jul 2, 2013, 09:27 PM
    Thank you everyone for your help! I checked into the Sure Seal and really like it. I plan on getting this!

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Second floor laundry room drain raised above floor [ 1 Answers ]

Please help! We recently moved into a new construction home. Unfortunately, our front load washer in our second floor laundry room recently continuously leaked for about 12 hours. It was a steady stream of water. Unfortunately, the drain installed by the builder is slightly raised, so...

2nd floor laundry room floor drain [ 2 Answers ]

My second floor laundry room has a pan under the washer connected to a 3/4" pvc pipe that terminates in the basement just below the subfloor of the 1st floor. I am finishing the basement and want to know the best way to handle this "emergency" drain. If I tie it into the sewer I will need a trap...

Ok to tie a wet bar drain into a drain pipe coming from 1st floor. [ 6 Answers ]

I'm finishing my basement in a newer house and want to add a wet bar. There is a 2" PVC drain pipe coming from the 1st floor that is for the washing machine drain. It has a clean out plug on it also. Can I just add a wye or Santee for the bar drain and do I need an Air Admittance Valve for venting....

2nd Floor, Floor drain backing up with water in restroom [ 1 Answers ]

I have a second floor restroom at my workplace and there is a little bit of water backing up and some sewer gas smell. There is rarely anything that goes down that drain but there is a little water in it that I can see. Also it seems that the urinals in the same restroom are draining very slowly....

Basement Floor Drain Question [ 2 Answers ]

I am in need of moving my current floor drain to the other side of a framed wall I just built to keep it in the same room as my hot water heater (per code) The current one will be sealed off. I can tap into the same line as it will be closer to the gray water crock. My question is, When I do...


View more questions Search