    Second floor gets really hot.
    This is a bit lengthy but bear with me.

    We bought a two level home with a finished basement. All 3 levels are zoned.

    The upper level has a hall that runs the length of the house. Six rooms (four bedrooms, a laundry room and a bathroom) come off that hallway. That hall has banisters and is partly open to the level below. THIS ENTIRE UPPER LEVEL HAS ONLY THREE COLD AIR RETURNS. One in the master bedroom, one in another bedroom and one at the end of the hallway. I think that's strange!

    In the summer, the heat elevates and this upper level gets HOT. Really HOT!The air conditioner can not cool it down. I believe the main problem is a lack of returns that would remove the hot air from this upper level.

    And now my question.

    The two bedrooms that do have cold air returns make use of the wall shared by the hallway. Could I cut into the wall in the hallway to add a register that would be on the opposite side of the register in the bedroom? Therefore, a run would have a bedroom and a hallway return. Thus, three returns would become five. Would this move more air out of the hallway and thus the upper level? Should I make these oversized registers to pull more air?

    Thank you for any help.
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #2

    May 2, 2013, 02:03 PM
    Before I would start cutting for returns, make sure you have plenty of attic insulation, R-30 and attic ventilation. If an attic gets really hot, radiant heat will not be carried away by airflow.
    hotupperlevel's Avatar
    hotupperlevel Posts: 2, Reputation: 1
    New Member
     
    #3

    May 2, 2013, 02:05 PM
    Blown in isulation (plenty) and ridge vents.
    ma0641's Avatar
    ma0641 Posts: 15,675, Reputation: 1012
    Uber Member
     
    #4

    May 2, 2013, 06:44 PM
    Only thing to remember regarding adding vents is that when you reach the supply volume, you cannot remove any more air, regardless of the number of vents. You should have a Test and Balance done to see what is the actual supply CFM and the return CFM. You may have a restricted airflow, dirty filters etc. Perhaps the motor speed could be increased for the air handler. Doors of rooms without returns should not be closed or have at least a 1-2"gap under the door. I would hate to see you do a lot of work without improving the temp.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Cold First Floor Hot second floor [ 1 Answers ]

I have a very cold first floor. My furnace is in the laundry room on the second floor of my home. It has a cold air register to the right side of it and there is another one downstairs in the first room of my house. My upstairs is very warm and we have tried to close all registers upstairs but...

1st and 2nd floor cold, third floor of home hot [ 1 Answers ]

I recently purchased a town home. 3 levels-1 garage -built in 1991. The basement is cold, but the second floor is cooler than the basement. The third level (where the bedrooms are located) is so hot that I open up a window. We noticed that the vents in the basement and one vent in the master...

Hot floor. [ 1 Answers ]

Why is my floor hot in vcertain areas?

Lukewarm hotwater on second floor (sink and shower) but other level hot hot water [ 4 Answers ]

Recently our shower (shower tub combo) with separate cold and hot taps started only giving luke warm water. The same goes for the hot water in the bathroom sink. This is only in the second floor bathroom. On the mainfloor (Kitchen and batheroom) the water is hot hot hot... in the basement...

Hot floor [ 2 Answers ]

Hello The floor in my downstairs bathroom feels hot. And also the faucet upstairs has a hiss like sound. And when I open my cold water ,I get hot water for 20-30 seconds then back to cold. I hope there is no leak under the house.thanks


View more questions Search