    Condenser Fan Motor Old 3-wire to New 4-wire Help Needed
    Hello, I have an A.O. Smith Condenser Motor and told this was the correct replacement. The old motor is 3-wire and the new motor is 4-wire. I have attached images. Can someone please explain which wires on the new motor go to the old connections.
    This is an image of the Wiring Schematic on the old motor
    2013-05-01_15-37-26.jpeg - EmmMay's library

    This is an image of the wiring schematic on the New Motor
    2013-05-01_15-37-44.jpeg - EmmMay's library

    My question is where do the new 4 wires connect in relation to the old 3 wires. I was told the Brwn/White wire is not used. But I Want to confirm and also verify that BlK goes to Blk, Brwn to Brwn and Then Yellow to Purple? Please help. Thank you in advance
    joseph townsend's Avatar
    joseph townsend Posts: 4, Reputation: 2
    New Member
     
    #2

    May 2, 2013, 11:26 AM
    What you have is a brown and brown/white which goes to a 5uf start capacitor. The black is to high line of the 230 contactor andwhite is to common of contacter. What I am saying is back and white well be your 230 volts and brown and brown white to run cap
    AnthonyCappa's Avatar
    AnthonyCappa Posts: 2, Reputation: 1
    New Member
     
    #3

    May 2, 2013, 03:21 PM
    Got it all sorted out. Thank you

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

How do I wire up my new AC condenser fan motor? [ 7 Answers ]

My new AC condenser fan motor has an extra wire. What do I do with it? AC is a 1996 SEER 12 Rheem. New motor is an A.O. Smith 1/8 HP 208 RPM 208-230 volt. Old motor has 3 wires, black, brown, and orange. New motor has 4. Black, brown, orange, and brown with a white stripe. Does anybody...

How to wire condenser fan motor [ 0 Answers ]

Old condeser fan motor 3 wires 2 went to old capaciter 1 to relay on defrost board,, new motor 5 wires I brown 1 brown w/white stripe,red low speed,black high speed and white should brown and brown with white stripe go to new (separate capacitor?) and red to defrost board and white to contacter?

How do I wire a new condenser fan motor [ 5 Answers ]

I have a Trane unit with GE condenser fan motor number 5kcp39fg. New condennser fan motor is A.O. Smith number F48k92A01. My question is on the old fan motor there were only 3 wires two for cap and looks like 1 for motor line and the new motor has a brown and brown/white for cap a black for line...

Replacing a Rheem 5 wire condenser fan motor with an Emerson 4 wire condenser Fan [ 0 Answers ]

I have a Rheem a/c unit that the fan motor quit. I took all the information off the old motor and went to a local supply store and they cross-referenced the numbers and gave me and Emerson motor. All the specs are the same, 1/5 HP, 1075 RPM, 60 Hz, 1.3 Amp, single phase. When I got home, I took...

How do I wire up a new condenser fan motor [ 5 Answers ]

The old condenser fan motor (EMERSON model # is K48HXFCN-3727,HP-1/8,v 208-230,rpm 1075with 3mfd 370vac dual capacitor) is making a noise.When I got a new one (EMERSON model#is K48HXTMG-4003 HP-1/8,v208-230,rpm1075 come with 5.0mfd 370vac capacitor). I am confused, I need help trying to do the...