    Ask a plumber
    My mother's flat-roofed 5 story building has a small interior patio with bedroom windows. The interior patio also has a vent stack that comes up from the ground floor. The stack pipe has been cut off at the level of the 1 metre wall that surrounds and protects the interior patio on the roof.

    When my mother opens the window that opens into the patio, there is a sewage smell. I presume that the denser sewage air sinks down into the patio well.

    I would like to put a couple of 90º sweeps to make a 180 bend over the patio wall and then a short piece of pipe downwards, say 50 cm, so that the sewage air will emanate below the level of the patio wall and hopefully be "taken away" by breezes or diluted and not go back down the patio well.

    My question is, will the 180º bend and the short downpipe affect the main vent stack's functions: allow air to enter to prevent negative pressures and to allow sewage smells to go out.

    Thanks, George Marsden (e-maill removed)
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Apr 22, 2013, 02:12 PM
    Hi George

    Plumbing code deals with this exact issue quite specifically by requiring vents in these circumstances to be run UP, above the highest wall that surrounds this pipe.

    Here, as unsightly as it might sound, this pipe needs to be run up above and be hung properly. The pipe can be painted or camouflaged by climbing plants or other things (or can act as a flag pole, etc.), but the correct answer is NOT to turn it back down on itself... needs to be run above the windows and/or wall for best/healthiest result!

    Hope that helped!

    Mark

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Ask a plumber [ 2 Answers ]

When I turn on my taps on all floors of my town house the water comes out but after a short while it spits air and the flow stops altogether.

Ask a Plumber [ 5 Answers ]

Just had a new Whirlpool gas oven delivered and was told they could not install because our old oven was hooked up with brass flex to flex connection through a partition(floor) and that was not code. Wanted to know if that was correct or if we have to hire a plumber to change out the brass flex to...

Plumber [ 1 Answers ]

My toilet tank won't fill up after each flush.. its making a whisp noice and I. have to fill it up myself

How do I become a plumber [ 3 Answers ]

I mean really I've been working on plumbing systems since I was 18 years old in the navy I was even oil king for 6 months controlling the balast of the ship ,I'm 34.I've worked in apartment and hotels and under the table jobs all my life.I can weld ,I know trigonometry, I have trouble shot a leaky...

Do I need a plumber? [ 8 Answers ]

The shower head is leaking badly. Do I need a plumber or can I fix it myself?


View more questions Search