New Member
|
|
Nov 13, 2012, 01:26 AM
|
|
Is a union necessary between two CPVC lines?
I'm replacing my old water heater and all the water lines in the house are CPVC. I'm wondering why there are unions on both the cold and hot lines near the water heater with CPVC running into and out of the unions. I thought unions were used to join different materials like copper and galvanized pipe because of the reactions between them. Is there some reason for them when all the lines are CPVC?
|
|
 |
Ultra Member
|
|
Nov 13, 2012, 02:07 AM
|
|
I use unions to make replacement easier with a valve on the side away from heater.
Shut of valves, disconnect unions and remove heater.
Put stubs from old heater into new heater. Reattach unions and turn on valves.
Good to go.
Chuck
|
|
 |
Eternal Plumber
|
|
Nov 13, 2012, 06:37 AM
|
|
Unless you have a special for wanting unions on your line they aren't needed. If you wish to join two lengths of CPVC a coupling is all you'll need. Good luck, Tom
|
|
 |
Uber Member
|
|
Nov 13, 2012, 09:23 AM
|
|
Unions are commonly used to join sections of threaded pipe since the threads oppose. Don't usually see them on CPVC but it is easier to open the line.
|
|
 |
Plumbing Expert
|
|
Nov 13, 2012, 11:41 AM
|
|
Unions are on both hot and cold water pipes to make water heater easier to remove. With unions installed, you don't have to cut pipes when replacing water heater. Hope that explains. Milo
|
|
 |
Home Repair & Remodeling Expert
|
|
Nov 13, 2012, 02:13 PM
|
|
I agree with using unions but I think the poster is talking about dielectric unions which are more expensive and unnecessary in this case
|
|
 |
Uber Member
|
|
Nov 13, 2012, 06:42 PM
|
|
Maybe they are heat traps, not dielectric unions?
|
|
 |
Eternal Plumber
|
|
Nov 14, 2012, 09:03 AM
|
|
All this is moot since the OP is piping in plastic. Unions of any kind aren't needed. And heat trap nipples will never be mistaken for unions. Regards, Tom
|
|
 |
Ultra Member
|
|
Nov 14, 2012, 11:27 AM
|
|
Hi Tom,
I agree with you that unions are not needed, but they do make replacement easier
Chuck
|
|
 |
Home Repair & Remodeling Expert
|
|
Nov 14, 2012, 06:09 PM
|
|
Nope, he said "join different materials like copper and galvanized pipe because of the reactions between them" those are dielectric but still totally unnecessary
|
|
Question Tools |
Search this Question |
|
|
Add your answer here.
Check out some similar questions!
Newly installed angle shutoff on cpvc leaking at cpvc
[ 7 Answers ]
I just installed a shutoff valve for a garage bath sink and I used primer and cpvc glue on the pipe (but not the inside of angle valve). Now after drying 3 hours, its leaking at the cpvc. Is there any way to fix/glue the leak without cutting off the shutoff and going back to store to get a new one...
Cpvc supply lines - securing before drywall?
[ 1 Answers ]
An odd question, I have framed my new laundry/half bath in the basement, all eelctrical ready to go and am ready to extend the plastic water supply lines for the future toilet/vanity. Question though, with this type of supply pipe, is there a need to secure it similar to pictures I have seen of...
Union and non-Union works
[ 2 Answers ]
What are the advantages and disadvantages of Union and non-union works in a Tool and Die industry? :confused:
View more questions