    Fan won't shut off in American Standard Freedom 80
    Bought house summer 2010. A/C has been working fine since then until past wkend. Compressor turns on/off as thermostat calls, but air handler fan stays on continuously.

    Fan stays on after removing thermostat (Hunter) from wall. Replaced thermostat. Took access panel off air handler, found White Rogers 50A65-475 IFC. Probed thermostat inputs (terminal block) on IFC with multimeter (holding panel kill switch closed). Found 25VAC on R (red), <1VAC on all other inputs, including G (green) and Y (Blue not Yellow in this case). Red LED on IFC blinks slowly. Fan running the whole time, except when kill switch opened. When kill switch closes, can hear relay on IFC close before fan comes on.

    My conclusion is drive circuit for fan relay is hosed and keeps relay and thus fan ON. I see replacements for IFC all over internet, but prices start ~$135, so I would like to see if there might be another answer.

    SO - does this sound familiar, and is there a cheaper fix than replacing the IFC? If the IFC can be repaired relatively easily, I have experience replacing parts on PCBs.

Check out some similar questions!

American Standard Freedom 90 4 blink code [ 3 Answers ]

I have an American Standard Single Stage Freedom 90 unit and just yesterday. It stopped blowing warm air. I have power cycled the unit and adjusted the thermostat and still nothing. The blower kicks on instantly and I don't see any spark or flame when looking at the venturies. My LED is...

American standard/trane furnace blower won't shut off . [ 0 Answers ]

Blower won't stop and burners not fireing.blower doesn't respond to thermostat control.tested pressure switch ,cleaned sensors,good filter.I'm not getting any trouble codes either , please help. A/C workes fine but blower still dosen't stop.

My american standard gas furnace fan won't stop blowing [ 2 Answers ]

My american standard gas furnace fan keep blowing after it reach it's desired temperature.

American Standard Evaporator Fan Motor Broken [ 2 Answers ]

Repairman said that the Evaporator Fan Motor (also called it variable speed motor) was broken and needed to order a new one. I'm trying to get a quote for the part but can't find this terminology. What is it called? Also, the unit was installed in June 2005 - do you think the part is under...


View more questions Search
 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.