    Plywood floor
    Two parts

    1. Having ripped up the kitchen floor tiles in my 1989 townhouse, the half inch expansion gap is on three walls only? The wall with the window has no gap? As I am fitting new plywood after taking up old plywood floor, should the window wall have a gap also?

    2. The current plywood floor is 1/2" thick, the solid wood strips I am laying require 3/4" plywood for the nails. Underneath the current plywood is another floor? I have no idea how thick although I can drill a hole to measure depth? Will I need 3/4 ply for the new floor, or will the second floor + new 1/2" plywood suffice?
    creahands's Avatar
    creahands Posts: 2,854, Reputation: 195
    Ultra Member
     
    #2

    Sep 4, 2012, 04:19 PM
    Welcome to AMHD

    1. When plywood is nailed and glued, movement will be limited if nonexisting. Would leave about 1/4'' on all walls.

    2. The one layer of 1/2'' u are putting down will be enough.

    Chuck
    Sticky Sam's Avatar
    Sticky Sam Posts: 76, Reputation: -2
    Junior Member
     
    #3

    Sep 5, 2012, 10:31 AM
    As I am fitting the plywood floor into my own kitchen, I want the best plywood for the new hardwood strips. Is it worth fitting plywood that is normally used in the kitchen units/cupboards itself? This plywood is much smoother. Also is pine plywood fine or will oak or other plywood be better?
    Sticky Sam's Avatar
    Sticky Sam Posts: 76, Reputation: -2
    Junior Member
     
    #4

    Sep 5, 2012, 11:49 AM
    Best wood type for plywood floor?
    I will be laying plywood underfloor before nailing down hardwood strips. Pine seems easily avaiable, is oak or other wood better for 8' x 4' underfloor sheeting? Also is it worth laying smooth plywood that is normally used for kitchen units/cupboards?
    creahands's Avatar
    creahands Posts: 2,854, Reputation: 195
    Ultra Member
     
    #5

    Sep 6, 2012, 05:24 AM
    Use AC plywood or one side good.

    Chuck
    Sticky Sam's Avatar
    Sticky Sam Posts: 76, Reputation: -2
    Junior Member
     
    #6

    Sep 6, 2012, 06:14 AM
    Chuck

    Ta for the info, however what is AC, what is one side good?
    creahands's Avatar
    creahands Posts: 2,854, Reputation: 195
    Ultra Member
     
    #7

    Sep 9, 2012, 08:26 AM
    AC plywood is plywood with one side that has the knot holes filled so that u have a smooth surface.

    One side good is plywood with no knot holes and has a smooth surface.

    Chuck

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Squeaky Concrete over Plywood Floor [ 1 Answers ]

I live in a condo. My living room floor squeaks. The floor has carpet over a concrete floor that was poured over a plywood sub-floor. Because I am on the second floor, I do not have access to my floor joists. How can I eliminate the squeaking? Thank you.

Old sub floor diff thickness than new plywood [ 16 Answers ]

Another problem I could use advice on. My subfloor needs replacing. I have attached a pic of the old floor. It is the diagonal floor planks that are very bouncy. I think they are about a little over a half inch. I don't know how to cut it flush to the wall and don't think I can. If I use a...

Gap between plywood and concrete floor? [ 2 Answers ]

If plywood is used to raise the level of a concrete floor that is in poor shape, does anything need to be done between the substrates? The concrete has extensive mastic and carpet glue problems. The plywood will more or less just be covering that floor to make way for something else but I am...

Tiling over plywood [ 2 Answers ]

:confused: Thank you for your answers;Clear-Mind-Web &Kstar4u, I can't seem to get my hands on the BC building code. But US code states 1" subfloor. A new problem has arisen about tiling over plywood... I forgot to mention this is also a heated floor which would create a lot more flex with the...

Tiling over plywood [ 2 Answers ]

The bathroom floor to be tiled is 5/8" subfloor with 1/4" ply ontop screwed every 6 inches.Iam trying to convince carpenter that this does not meet code, nor is it a proper base for tiling. I want him to put down hardibacker (1/4") but he has convinced home-owners not necessary. What do I do?...


View more questions Search