    Cast iron hub plug
    I have 90 year old home with cast iron waste pipes. One 2nd floor bath sink gurgles, after cutting into wall behind sink I have cofirmed the obvious... sink isn't vented. The cast iron waste pipe rises 6" above the sink drain with a hub. This hub is filled with a very hard chocky white stuff. Doesn't seem to be sandy, so could this be concrete or some other 1920's pipe filler? Is drilling with concrete bit the only solution?
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #2

    Mar 5, 2012, 09:32 PM
    Don't know where you live so this may not be allowed by your local plumbing code. You could solve the issue by installing a Studor vent or AAV. Has this sink always gurgle every day since you moved in?
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #3

    Mar 5, 2012, 10:47 PM
    I agree with Bob that an AAV under the sink is the best approach. However, if it is you desire or intent to install a proper vent line, I wouldn't try drilling out what ever was used (probably plaster) to seal the old cast. There must be a tee where the sink drain meets the drain pipe. I would try removing that section of pipe at that joint and using PVC to vent. Is that section of pipe cast iron or galvanized iron pipe. If galvanized I would cut it below the sealing material and convert to PVC with a rubber coupling.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Mar 6, 2012, 06:26 AM
    A little note.
    Codes mandate that if you use a AAV that it must be assessable for service or replacement. In other words you can't seal it up in a wall. Good luck. Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Cast Iron Hub Type P Trap [ 4 Answers ]

I want to replace a cast iron hub type P trap in a basement location used for a shower drain. The new drain is to be ABS or PVC to accommodate a tile or cultured marbel shower base. The drain is 1 1/2" cast iron. First how is the pipe removed from the hub? I asume it is filled with lead and oakuj....

Connecting a PVC to a cast iron hub? [ 1 Answers ]

First of all thanks for the help on my previous question. I found diamond tiped sawsall blade to cut the cracked castiron pipe. But my confidence is still low. I looked at the pipe again to see how far the crack is. The 3" castiron pipe has a vertical crack that goes very close to the castiron hub...

Sealing with cast iron hub donut? [ 10 Answers ]

Following the sage advice found on this site in other postings, I managed to remove the misshapen, rusted waste pipe that went from my downstairs toilet to the horizontal main line (cast iron). So now I have a cleaned out bell and test fitted a neoprene donut from Lowe's (4" to 3") and plan on...

Best way to stub out from a threaded cast iron hub? [ 2 Answers ]

I just (painfully) removed a chrome pipe + solder bushing from a cast iron hub. I bought a Desanco fitting to transition between the cast iron and a chromed brass tailpipe (this is for a wall-hung lav). The problem is that the hub (I don't know if that's even the right word for threaded cast...

Joining hub and spigot with no-hub cast iron pipe [ 4 Answers ]

HELLO GUYS, I have a question I hope you could help me. I have an old piping, CAST IRON hub and spigot. It is installed underground with the bell portion protruding for insertion of the soil stack. I would like to use no-hub cast iron pipes for the upper part of my house. Can I easily insert the...


View more questions Search