Ask Experts Questions for FREE Help !
Ask
    DBAND's Avatar
    DBAND Posts: 1, Reputation: 1
    New Member
     
    #1

    Feb 15, 2012, 11:24 AM
    Kenmore Electric Dryer MODEL # 110.63912100 Won't Stay Running
    I cleaned the lint drap and duct and put everything back together. Now dryer runs for a second then shuts off. I checked the wires on the lint trap sensor and they are connected where they should be. Any ideas?
    drtom4444's Avatar
    drtom4444 Posts: 3,282, Reputation: 145
    Ultra Member
     
    #2

    Feb 16, 2012, 10:39 AM

    It's dirty and lint deposits have built up, as it always does, in all the air ducts which cause the main safety to trip. A little vacuuming out does nothing. You will have to take it apart and clean it really well. You will have to clean the drier out thoroughly or it is all for nothing. Every air duct will have to be removed and scraped and washed out to remove baked on lint deposits which is like a concrete lining. This will burn so the manufacturer has installed the safeties to keep from having a house fire. The safeties are oval-shaped with a round center part containing the safety with two plug-on terminals for the wires and when they burn open or trip, from the dryer being dirty, nothing will work. Using an ohm meter you put a lead on each terminal of the safety, with one wire unplugged, and if it's good you will have a reading of about zero; if it's bad it will read infinity. Driers were the number one cause of fires at one time, hence now we have safety fuses. Apparently yours is resettable. Look at: http://www.youtube.com/watch?v=MMP7BW1lLs4 to see how. Also: http://www.youtube.com/watch?v=iBiRw-KElC4 ; http://www.youtube.com/watch?v=yFTZGgVisCI
    http://www.electrical-forensics.com/Dryer/ElectricClothesDryers.html
    http://fixitnow.com/wp/2010/10/09/whirlpool-dryer-model-le5800xsw3-wiring-diagram/
    When you finish cleaning the drier it is best to also replace the belt, too, because you do not want to have to disassemble it all over again and if the belt is over two years old you should replace it.

    Note that on most of the videos it does not show them washing out the parts, but this is important because it's the only way to really get the parts clean, just don't get motor wet or the capacitor if it has one. Vacuum out the motor to remove all dust. I would move the drier out to your garage to have plenty of space to work. You also want to check your vent and clean it, also. The vent should have a short run and be straight as possible. The job is really easier than it sounds. There is no shortcut that will work; it has to be cleaned well. Before you re-assemble it make sure to use white lithium grease (high-temp grease) and grease all bearings. DrTom4444

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

I have a Kenmore Electric Dryer 110.63954102 that won't stay on and has no heat... [ 3 Answers ]

I have a Kenmore Electric Dryer 110.63954102 that won't stay on and has no heat when you hold down the start button to keep it on; is this an expensive repair?

Kenmore Electric Dryer Model no 110.63932101 does not heat in Auto moisture sensing [ 1 Answers ]

The dryer functions all seem to work OK. The dryer will dry (normal heat)when set to "Time Cycle" but will not dry (no heat) when set to "Auto Moisture Sensing Plus cycle". What part should I look for to replace.

Kenmore HE4 electric dryer model 110.85876400 [ 1 Answers ]

My unit runs but doesn't appear to be heating up the clothes are not drying? My guess is it's the heating element, but any help is greatly appreciated.

Kenmore electric dryer MODEL # 110.63912100 won't get hot while running [ 1 Answers ]

My kenmore electric dryer model # 110.63912100 won't get hot while running. What could be the problem?

Kenmore Elite Dryer Model # 110.63952101 won't stay running [ 3 Answers ]

I have a 3 years old Kenmore Elite Dryer (Model # 110.63952101). The dryer can be started and will heat, but shuts down after 1 to 2 monutes. It seems like a control problem. What do I need to replace?


View more questions Search