    Sewage pump and check valves
    Do I need to use a check valve if I am going from a sump pump to a sewage pump? The septic exit site is only about 5 feet above the top of the ejector pit.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Feb 5, 2012, 07:36 AM
    If the sump pump's outlet is lower then the inlet to the ejector pit the answer's yes. You'll need a check valve to prevent backflow. Good luck, Tom
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #3

    Feb 5, 2012, 07:40 AM
    With a sewage ejector you want to install a check valve to keep the last bunch of sewage water that gets pumped up from falling back into the ejector pit... why pay to pump it out twice, right?

    You should also install a 2" PVC butterfly valve above the check valve so you can service both the pump and the check valve should either fail/malfunction in the future... ;)

    Good luck!

    Mark
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Feb 5, 2012, 08:28 AM
    This may help.
    Attached Images
     

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Sewer Pump Check Valves [ 4 Answers ]

I've had significant issues with my sewer alarm going off every few months. The plumber recently replaced the check valve. A second plumber (passing through) told me that my brass, "spring" check valve on a vertical pipe should have been in a horizontal position and should be a "swing" valve not...

Ejector Pump, Check Valves and Installation [ 8 Answers ]

I have recently bought a 1966 home in Louisiana. One side of the house is about 4 feet below grade and the downstairs bathroom feeds outside into a 8 foot cement drain pit that has an ejector pump that shoots the sewage out to the street/city sewage. I have a local plumber helping me (albeit...

Silent sewage pump check valve [ 4 Answers ]

Can anyone recommend a high quality silent sewage pump check valve for a 2" pipe?

Installation of Check Valves and Gate valves [ 2 Answers ]

Where is the ideal location to install Gate valves and Check valves for a domestic water supply system?


View more questions Search