    How do I reolace water line from copper to pvc for faucet hook up?
    How do I replace water line from copper to pvc for faucet hook up?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Jan 27, 2012, 06:46 AM
    Are you saying that all that comes out of the wall is a copper pipe? There should be a angle stop (see image) on the end of that \copper pipe. Is the copper pipe capped off? More details please. Tom
    Attached Images
     
    bsh4327's Avatar
    bsh4327 Posts: 3, Reputation: 1
    New Member
     
    #3

    Jan 27, 2012, 07:08 AM
    Cooper pipe came up through floor, I have put on transition union and have copper pipe from pvc to faucet. I now have pin hole in copper on elbow. I want to take pvc up to a 90 elbow and hook up to flexible faucet hose.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Jan 27, 2012, 07:24 AM
    If I understand you correctly you're asking how to convert from copper to PVc. Correct? Purchase a Sharkbite male adapter in the correct size.)1/2"?) and as PVC female adapter along with small cans of PVC primmer and cement. Does that answer your question? Tom
    bsh4327's Avatar
    bsh4327 Posts: 3, Reputation: 1
    New Member
     
    #5

    Jan 27, 2012, 07:28 AM
    Some what. It is a 1/2" water supply to kitchen faucet, but the flexible line to the faucet itself is smaller with a metal nut. I can't hook metal to pvc fitting, correct?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #6

    Jan 27, 2012, 07:54 AM
    The you install a inline compression stop on the raiser. The small metal nut will connect to the outlet. Good luck. Tom
    Attached Images
     
    ghanson59's Avatar
    ghanson59 Posts: 3, Reputation: 1
    New Member
     
    #7

    Jan 28, 2012, 07:41 AM
    I also recommend a Sharkbite adapter for attaching to the copper. They take only a moment to install and the four I used recently never leaked a single drop.
    Skip the PVC and run your flexible hose right to the Sharkbite. When I replaced faucets in our master bathroom I used 1/2" to 3/8" Sharkbite 1/4 Turn Angle Valves and flexible hoses with 3/8" on one end and 1/2" on the other (1/2" goes to faucet). Quick, easy (no cursing from me!), and as I said before, not a drop.
    (BTW, I'm not an expert. I'm just a guy who haunts this forum for help.)

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Convert copper faucet water line to flexible [ 2 Answers ]

I have a bathroom faucet that has long copper supply lines. Can I cut them and fit flexible tubing to them to fit them to the shut off valves?

Can I replace my flexible faucet line with a copper line? [ 2 Answers ]

Yes, that's right I would like to replace my flexible line with a copper line? How easy would this be and is it possible? Reason I need to install a saddle valve to hook up to a ro/di unit.

Is it possible to connect PVC to a 3/8 soft copper line? [ 3 Answers ]

Is it possible to connect PVC to a 3/8 soft copper line? I'm creating a misting system out of PVC but I want to connect it to my city water supply, I'm not sure how to connect the two pipes best, I'm assuming soldering wouldn't be good, so I was thinking PVC glue or threading them somehow.

Loud Bangs Coming from PVC waste pipe and Hot Water Copper Line [ 6 Answers ]

A year ago I had a crack and leak in our PVC waste pipe just behind our family room wall close to the first story floor. The plumber opened up the drywall and cut out the cracked portion (2 feet) which exended from just behind the family room wall down to the basement and replaced it with a new...


View more questions Search