    Correct washer for metal flanged toilet "water supply line"?
    I am installing a Fluidmaster Fill valve.. I have a metal flanged water supply line. Instructions say to use the existing coupling nut (have to.. Can't get it off anyway) and the existing washer. If this existing washer is a flat washer that sits on top of the flange, there wasn't one when I disconnected it. When I hooked it up and tightened the coupling nut, with a wrench, as tight as I could,there is a leak around the coupling nut. I'm assuming I need a flat washer to sit on top of the flange.. What size/type of washer do I need? Or is there something else that needs to be done?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Jan 15, 2012, 09:57 AM
    OK! Here's a toilet supply, (see image) They're all the same. The small nut will connect to the outlet of them angle stop and the large nut should have a plastic built right into the nut. If you don't have that washer return it and get another.
    Now for your leak. If the supply you installed doesn't have a washer you have found your problem. Replace the supply. But there's another reason you could have a leak. It's very easy to cross thread plastic threads. It will tighten down but leaves a tiny opening that will leak. If your supply has a washer then take it apart and try installing it again. Good luck, Tom
    Attached Images
     
    Chuxter's Avatar
    Chuxter Posts: 4, Reputation: 2
    New Member
     
    #3

    Jan 15, 2012, 10:17 AM
    Thanks for responding.. The issue is that I do not have this type of supply line.. I have a flanged metal tube.. There is suppoded to be a washer that sits on ope of the flange, which then seals against the threaded shank of the fill valve assembly, as the brass coupling nut is tightened... Fluidmaster instructions said to use the "exisiting" washer from the old hookup with this type of water supply line. My old one had either disintigrated or was not originally installed. Fluidmaster illustrates this washer as a "flat" washer. My question is, "what size/type flat washer do I need??" Thanks..
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Jan 15, 2012, 10:41 AM
    Is this what you have? (see image).
    Let me know, Tom
    Attached Images
     
    Chuxter's Avatar
    Chuxter Posts: 4, Reputation: 2
    New Member
     
    #5

    Jan 15, 2012, 11:29 AM
    Yes! That is the tube I have.. Thanks
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #6

    Jan 15, 2012, 12:09 PM
    The yellow insert is the washer. But wait! You're doing it the hard way. Take it back and pick up a supply O have put up in post #2.

    Much easier to work with. Good luck, Tom
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #7

    Jan 15, 2012, 03:09 PM
    Yup! Even if you were successful in getting the right washer (could just buy the smallest metal toilet supply and swap the washer) the other parts (nut/ferrule) have been compromised and will probably cause trouble for you here.

    As Tom said, buy a new flexible supply... has rubber cone washer inside the nuts at both ends of the toilet supply! Tighten each nut end hand tight plus a 1/2 turn or so and then test your work.

    Good luck!

    Mark

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

"Form" placed in "Microsoft Access" can be accessed from a "Button" in "VB.Net" App [ 1 Answers ]

Hi All, Actually, I'm not very well in programming but a task is assigned to me related to .Net. Basically, there is a database in Microsoft Access. I have made forms in it which are based on queries to retrieve required results. I have also made graph of it. Now, I have to merge this...

How to connect P trap of ceramic toilet to 4" or 3" PVC Line [ 4 Answers ]

We have some questions on how the P-trap toilet connect to the outside waste line . We want to know which parts to fit that or tell us how to connect the P-trap to a 4” or 3” line?

Commercial toilet with 3/4" supply line? [ 9 Answers ]

Hi all, I want to install a wall-mount toilet in my residential bathroom that is currently stripped to studs. To use a Duravit or Caroma, I would need to move the vent stack and studs to allow room for the in-wall tank, so I am exploring using a commercial toilet instead. Toto has a 1.28 gpf...

Changing wiring to use "second line" rather than "first" line on specific jack [ 9 Answers ]

Hi, and thanks! I have two phone lines (telephone numbers) coming into the house. I want to change a particular jack from one line to the other (exclusively for a fax). The current jack has a pair of tan wires going to "black (heavier wire and screw)", a pair of blue wires going to "red", a pair...

Periodic "gushing" noise in main water line [ 1 Answers ]

In my basement, the main water line comes in through one of the basement walls. I don't think I've heard this before, but periodically, I hear water rushing noises coming from the line. When I go down to the basement, it's like water is rushing in, stopping, then rushing in, etc... Could be...


View more questions Search