Ask Experts Questions for FREE Help !
Ask
    danny10's Avatar
    danny10 Posts: 1, Reputation: 1
    New Member
     
    #1

    Jan 14, 2012, 08:41 AM
    My fan blower doesn't shut off
    I just replace a control board in my rheem gas furnes I got a uthec but I replace with a universal control board is working and everything but don't shut off wath could be
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #2

    Jan 14, 2012, 06:45 PM
    You tell me exactly where every wire is hooked to the new board, or better yet, post a couple of really clear pics, and Ill see what I can do for you. But first, unhook all themostat wires from the board and see if the blower will shut off. If it doesn't, hook them back up like you had them. I will also need to know if it is the draft inducer motor running, or the main blower motor. Im betting something got miswired, or, worst case, the board isn't compatible with our furnace. Just a thought, but it is never a great idea to use a universal board, factory new replacement boards are really the best way to go, but lets give this a shot anyway, okay?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Blower fan will start and shut down [ 0 Answers ]

Wires burnt to unit-i repaired wiring,and installed 3 amp fuse-blower I have to push relay to get outside fan to come on,blower fan will come on and will cut off instantly

Heat pump blower fan won't shut off. [ 2 Answers ]

I have a heat pump with an older model thermostat. I just moved in here and the heat pump was already here, although it didn't seem to be properly taken car of at all. It still blows warm air when it is needed and works great as a central air conditioner, but the blower fan doesn't cvut off like it...

Furnace Blower Fan will not shut off [ 2 Answers ]

Furnace blower fan will not shut off

Blower fan will not shut off. [ 1 Answers ]

I have a York LP gas furnace and heat pump. The furnace fan will not shut off even if I turn thermostat to off position. I took the thermostat apart and it has a mercury switch for the temperature side, the mode side is not accessible. The furnace seems to work.

Carrier furnace blower fan doesn't shut off [ 1 Answers ]

Hi my carrier furnace the blower fan that circulates air through the duct work doesn't stop running Thanks jim