Ask Experts Questions for FREE Help !
Ask
    oliverok's Avatar
    oliverok Posts: 2, Reputation: 1
    New Member
     
    #1

    Dec 29, 2011, 05:41 AM
    2" PVC vs. 1 1/2"
    When is it necessary to use 2" PVC SCH 40 drain lines instead of 1 1/2"? I'm assuming it has to with the volume of water/number of fixtures draining into it. Any info would be appreciated!
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Dec 29, 2011, 05:48 AM
    We haven't used 1 1/2" drainage for some years now. And in some codes the kitchen drainage is increased from 2 to 3". You are correct, 2" will carry more volume and have less clogs. Why do you ask? Regards, Tom
    oliverok's Avatar
    oliverok Posts: 2, Reputation: 1
    New Member
     
    #3

    Dec 29, 2011, 06:32 AM
    Oh wow, OK. I thought 1 1/2" was pretty standard on kitchen/bath waste lines but I'm far from being a professional. I'm plumbing a kitchen/utility area that has a double bowl sink, DW, another smaller sink, and a utility tub. The main soil pipe is 4" cast iron and there's a 2" galv. arm that Ys off of it that reduces down to 1 1/2". The previous owners threaded a PVC female adapter onto it. I tried to unthread the 1 1/2" galv. reducer off to get to the 2" and run 2" PVC from there but half a can of liquid wrench later and it wouldn't budge with the pipe wrench so I pretty much had to go 1.5" from there--especially since I didn't want to chisel out the lead and bushing from the cast iron and try to do a rubber bushing or something like that. Nothing is glued yet, just dry fitting everything so I can go to 2" but it would just be increasing it at the 1 1/2" galv. So it would still technically be draining into a smaller line. Also, you eventually have to reduce to 1 1/2" before the sink traps right? or do they make 2" slip joint connectors? Sorry if this seems muddled, again thanks for any expertise you can lend.
    Ollie
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Dec 29, 2011, 07:15 AM
    you eventually have to reduce to 1 1/2" before the sink traps right?
    Yeah! For a few inches until the 2
    Trap. This is not the same as running 1 1/2" all the way to the 4"
    Main. I hope you're not planing on adding a disposal. This wouldn't be a good idea. As for using 1 1/2" for your kitchen drain, for years we used 1/2" drainage, however with dishwashers and disposals the volume was too much for 1 1/2". If you don't add appliances on the drain line you should be OK.
    However, If you wanted to increase to 2" PVC you could cut out the bushing and convert to PVC using a 2" shielded clamp.(see image) Good luck. Tom
    Attached Images
     

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

"Form" placed in "Microsoft Access" can be accessed from a "Button" in "VB.Net" App [ 1 Answers ]

Hi All, Actually, I'm not very well in programming but a task is assigned to me related to .Net. Basically, there is a database in Microsoft Access. I have made forms in it which are based on queries to retrieve required results. I have also made graph of it. Now, I have to merge this...

How to connect P trap of ceramic toilet to 4" or 3" PVC Line [ 4 Answers ]

We have some questions on how the P-trap toilet connect to the outside waste line . We want to know which parts to fit that or tell us how to connect the P-trap to a 4” or 3” line?

Tub Drain -- 1 1/2"pvc to 4" cast iron with hub [ 12 Answers ]

Hi . . . I'm replacing my old cast iron tub with a whirlpool tub. The old drain was a 1 1/2" brass tube tucked into a 4" cast iron drain pipe (with hub), packed with what might be oakum. The seal was fibrous and waxy when I cleaned out the drain, and that's not MY hair :) What's the best way...

Attaching new 2" drain pipe to existing 3" soil stack - PVC [ 4 Answers ]

All, I am installing an additional sink on the main level of my home. On the lower level, below, there is a main 3" soil stack. I am thinking to use a 3"x2" Y connector to tie 2" drain pipe into this main soil stack. The sink will be vented using AAV (island) Questions: 1. Is there any...

Adding a PVC "Y" to a underground Cast iron pipe [ 1 Answers ]

I have a house built in 1962. The cast iron waste pipe runs under the concrete slab in the basement. I have already dug and confirmed the location I want to cut a section out of the pipe and install a "Y" connector and run new plastic waste pipes to a new bath. I have seen PVC connectors that...


View more questions Search