Ask Experts Questions for FREE Help !
Ask
    dkrob74's Avatar
    dkrob74 Posts: 2, Reputation: 1
    New Member
     
    #1

    Mar 6, 2010, 06:49 AM
    How to vent plumbing in basement bathroom
    I built a bathroom in my basement... shower, vanity, and toilet. I had to buy a pump from Lowe's designed for this renovation. For it, I had to build a raised floor for the installation. The pump is designed to attach to where the toilet sits. My main sewer drain is about 5' up the wall behind. The pump was plumbed to drain to it. My question is the venting for it. I tried a studor vent, but it won't work, because of no air getting in for the pump. It won't let the toilet flush. Am I going to have to run pvc and tie into the main vent to my shower upstairs? Thanks.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Mar 6, 2010, 09:39 AM
    Quote Originally Posted by ;
    Am i going to have to run pvc and tie into the main vent to my shower upstairs?
    That will vent your fixtures. However the pit vent MUST BE DEDICATED and not connected to anything. I have put up a image of ejector pit venting. If wet venting's allowed in your area you may connect the shower drain to the lavatory drain and let it be wet vented by it.
    Attached Images
     
    dkrob74's Avatar
    dkrob74 Posts: 2, Reputation: 1
    New Member
     
    #3

    Mar 7, 2010, 09:05 PM
    Quote Originally Posted by speedball1 View Post
    That will vent your fixtures. However the pit vent MUST BE DEDICATED and not connected to anything. I have put up a image of ejector pit venting. If wet venting's allowed in your area you may connect the shower drain to the lavatory drain and let it be wet vented by it.
    Yes your answer and image helped. But, are you saying that I can't tie in the pit vent with the vent that runs up behind my upstairs shower then through the roof?
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #4

    Mar 8, 2010, 01:00 PM

    are you saying that I can't tie in the pit vent with the vent that runs up behind my upstairs shower then through the roof?
    That's exactly what I'm saying.
    The vent servicing the ejector pit must be a dedicated one.
    The lavatory vent must be separate from the pit vent. The reason for this is while the lavatory and fixture vents just pull outside air into the system to relieve the suction caused by draining waste the pit vent must push air out while the fixtures are discharging into the pit it must also pull air in while the ejector pump's pumping the pit out. It's not good plumbing practice to introduce pressure into a venting system designed to operate under suction.
    Run a separate vent on the pit.
    Good luck, Tom
    vega21's Avatar
    vega21 Posts: 1, Reputation: 1
    New Member
     
    #5

    Dec 14, 2011, 04:02 PM
    I built a bathroom in basement with sink,toilet,and shower.. my question is how to run venting pipe?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Vent questions for new basement plumbing [ 1 Answers ]

This is going to be a mess I can see it all ready. Here it goes. I have planned out my basement and I am putting a full bathroom, washer and kitchen in. I am planning on cutting the vent through an existing upstairs closet (so I can hide it and later frame a plumbing chase around the pvc). The...

Plumbing vent for a second floor bathroom [ 3 Answers ]

I am relocating my second floor bathroom to an adjacent room. My main drain stack runs up vertically in one corner of the new bathroom. While my toilet and bidet which will be located side by side along the drain stack(that vents through my roof) and can be vented with a conventional loop, my...

Basement Bathroom Vent [ 6 Answers ]

I am finishing my basement. It has roughed-in plumbing under the slab for a bathtub, sink and toilet tied to pit for a sewage ejector pump to pump up to the municipal sewer. There is a 2" capped PVC pipe protruding from the first floor bathroom, which is directly above this bathroom. I am...

Basement bathroom plumbing [ 2 Answers ]

Hi, Could someone please tell me whether my basement bathroom drainage is properly vented? Note that I am not concerned about building to code, I just want it to work. If you are interested in answering this question, I'll email you the drawing, because this forum will not accept an upload of...

Basement bathroom vent [ 5 Answers ]

I want to put a shower, sink and toilet in a basement I am developing. When they built the house they did not rough in any plumbing nor did they run a vent to the basement. After I break up the concrete to install the drains I still have the venting problems. Can I run a vent line horizontally out...


View more questions Search