Ask Experts Questions for FREE Help !
Ask
    mckenzif's Avatar
    mckenzif Posts: 2, Reputation: 1
    New Member
     
    #1

    Oct 8, 2011, 01:13 PM
    Will the venturi jet in the foot valve cause low pressure from your water pump
    I have a Goulds JRD5 Convertible water pump. Well is 28 ft. Deep but is located 35 ft. From the house. I have 2 lines running to the well with foot valve and jet down in the water. Pump has been working fine for several years. Can not get over 30 PSI out of the pump now for some reason. Don't know if it's the pump for jet down in the well. New pressure gauge. How can I determine what is causing low pressure from the pump.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Oct 9, 2011, 07:15 AM
    When you shut the pump off does the gage drop to zero? Does the pump keep running attempting to bring it up to the cut off point? What's the cut in/cut out setting on your control box. Back to you, Tom
    mckenzif's Avatar
    mckenzif Posts: 2, Reputation: 1
    New Member
     
    #3

    Oct 9, 2011, 05:33 PM
    Pump is currently running continuously at 25 lbs. Pump does not drop back to zero when I turn it off. Gauge remains at 25 lbs. I pretty sure I have a 20 (cut in) - 40 (cut out) lb. pressure switch.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Do all wells have a foot valve? Our well is about 25' deep & we have Flotec jet pump [ 25 Answers ]

We are trying to figure out if our well has a foot valve or if it just has the check valve in front of the pump (jet pump in basement). We lost water all of a sudden. We found a hole in the suction line & we have replaced that section of the suction line? We used the plumber's puddy on the joints...

My well water jet pump when priming it loses pressure at 15psi over and over again [ 1 Answers ]

My well water jet pump when priming it loses pressure at 15psi over and over again

If my foot valve is bad would my pump hold pressure at all? [ 2 Answers ]

Its winter and I'm having issues keeping water pressure in my system. Sometimes I can get it but as soon as the pump kicks on the pressure fluctuates dramatically and then goes to 0 and stays there. I then close the valve between the pump and pressure tank so I can prime the pump. When I check...

Does shallow well jet pump build air pressure in the bladder or just water pressure? [ 0 Answers ]

My 40/60 3/4hp shallow well jet pump will run continuously and will not build up air pressure in the bladder. The bladder will hold pressure though. I have filled it with air and when I turn on the water it loses its pressure and when the pump kicks on it just keeps running without building the...

I can't get my jet pump to prime and my foot valve is working correctly [ 1 Answers ]

5 days ago my hubby was drilling holes for a garage and hit our water line he repaired the break in the feed and return line, we tried to prime the pump and we cannot get the pressure to build like it should. We have checked to repairs to make sure they are not leaking... nothing 5 days later we...