    Galvanic corrosion and copper pipe
    Does galvanic corrosion on a hot water copper pipe travel from point of contact, 2' 10' 20' in solid or spotty patterns in both dirrections. Is it more pronounced elbows and fittings. Would a galvanized chain attached to a copper hanger (chain not touching the pipe) or galv chain supporting the pipe separated by rubber so there is no contact be a problem. I don't have a picture but at first look the greenish pattern looks as if the plumber had dirty fingers (flux) and years later these fingerprints turned green running down the pipe but covering the fittings and more so near the ends
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #2

    Oct 5, 2011, 05:33 PM
    Rubber separating the galv from the copper would be just fine. The green you see is most likely just what you suspect, leftover flux. If its not leaking, I wouldn't worry too much about it. It certainly doesn't look good, but usually is harmless. If you are worried about the pipes being weak, shut the water off, and give the pipe a good poke with your pocket knife. If the pipe dents easily, or you can poke your knife through it easily, you have a problem. If it seems nice and rigid, you should be okay for years to come.
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #3

    Oct 5, 2011, 06:34 PM
    Greenish copper is no big deal. Grab a flashlight and look at the printing on the sied of the pipe, what type is it. Type is L, M or K
    Milo Dolezal's Avatar
    Milo Dolezal Posts: 7,192, Reputation: 523
    Plumbing Expert
     
    #4

    Oct 6, 2011, 03:23 AM
    The Dirty Fingers theory may be it. The greenish "stuff" on and around copper fittings indicates that plumber didn't wipe off flux after soldering. Take steel wool and clean it. Milo.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Attaching copper faucet to copper pipe attached to plastic pipe? [ 1 Answers ]

I have plastic piping in the house which leads outside and then copper piping is outside with a facet attached.. I need to change the facet with torch and solder... if I heat the old one to remove with this heat travel down the copper pipe through the wall and affect the plastic pipe.. I am worried...

Galvanized pipe to either Copper/CPVC pipe [ 14 Answers ]

I had a leak in my cold water feed which happens to be galvanized pipe. It was between 2 floors and I cut out the affected section. I am going to replace the cut out section with either copper or CPVC. But how does one connect unthreaded galvanized pipe to the after mentioned pipes? I don't know if...

Corrosion concern between brass ball valve and galvanized steel pipe [ 2 Answers ]

Is it going to cause the corrosion when connecting a galvanized steel nipple to a brass ball valve?

A/C not cooling, Small Copper pipe COLD and Large Copper pipe room temp. [ 4 Answers ]

I just moved into a newly constructed townhome and the a/c units are of course new. The A/c is not cooling at all. The machine inside turns on as well as the one outside. The inside A/C makes a strange sucking sound kind of like if you were sipping something out of a cup with a straw and you ran...


View more questions Search