    I have an intertherm in a mobile that is 11 years old!
    The ceramic pilot will only heat up when I pinch one hose and the unit will fire up when I pinch off the other hose. What is causing it!
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #2

    Aug 30, 2011, 03:41 PM
    Check vent for blockage (birds nest etc at vent termination on roof). The hosed you are pinching are going to the pressure switch I assume. It may also be as simple as a bad pressure switch. It could also be a bad draft inducer. Worst case, cracked heat exchanger. I would call in a tech to look the system over and solve the problem. Lots of variables here. Hard to trouble shoot over the net. Good luck and please do let us know how things turn out.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Intertherm mobile home furnace [ 1 Answers ]

I have to change thermo couple and spark electrode in my furnace, but don't know how to access furnace. It's built into wall, so I need to know access door or easiest way. Model #MG8-065-AACWL-05. Any help at all is much appreciated,thanks

Intertherm mobile home gas furnace [ 1 Answers ]

How can I clean the heat exchanger on an intertherm m1mb090bw gas furnace. I have vacuumed it out from the top where the pipe attaches and also from inside the fire box but it is still restricted.

Intertherm system for mobile home [ 1 Answers ]

Intertherm air conditioner/ furnace in mobile home. Furnace worked fine blew heated air - air conditioner comes on outside but does not blow inside. Air conditioning unit checks out fine - why does it not blow inside?

Filter for 1985 Intertherm (Mobile Home). [ 1 Answers ]

Hello. I don't really know anything about air condition/heating units, but I'm really hoping someone can help me soon. I'm living in my own mobile home as of a couple months ago (it's a 1985). When I arrived here, there was a large (24x24, I think) filter (made of cardboard and that blue filter...

Mobile home with a Intertherm [ 1 Answers ]

I have a inthertherm furance model #MBBB-066ABFC-09 in my 1999 doublewide Mobile Home. I had a serviceman here twice last year to see if they could figure out what was causing the fan to have these short runs then it would turn off several times before it would continue to blow. Then after it got...


View more questions Search