Ask Experts Questions for FREE Help !
Ask
    basec0m's Avatar
    basec0m Posts: 2, Reputation: 2
    New Member
     
    #1

    Aug 28, 2011, 08:00 AM
    Dog chewed my A/C wires outside. Can anyone help?
    Can anyone save me some money for this simple fix? The dog chewed the wires from my a/c unit outside. There is a white, green, and red wire that are disconnected. There are two yellow wires that come off the contactor. Neither of these are connected to anything. Which wires do I reconnect? See wiring diagram and picture.



    Stratmando's Avatar
    Stratmando Posts: 11,188, Reputation: 508
    Uber Member
     
    #2

    Aug 28, 2011, 10:37 AM
    If he chewed the wires while it was on Cool, he may have shorted the transformer/fuse?
    Does inside blower work or any response from Thermostat. If not, 24 volt transformer fuse in air handler needs to be replaced. Cap the ends of the wires first, while in there, you may see what colors are being used and which is capped, if any.
    If only 2 wires are used, then set unit to cool, and see which of the 2 wires have 24 volts AC, then Turn Off inside unit so you don't blow a fuse again make connections, doesn't matter which. Turn unit back on.

    I always pull control wires with supply so they are protected in conduit. Not All Electricians/AC Guys do this.

    The control wires connect to the yellows in the little compartment.
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #3

    Aug 28, 2011, 04:10 PM
    I agree with Strat. My guess would be that the red and white hooked to the yellows, but best to look in the furnace inside and see which wire was not used. Now, of the two wires that are hooked up inside (should hook to y and c terminal). Just hook one wire to one yellow outside, and the other wire to the other yellow (doesnt matter which goes where).
    Fr_Chuck's Avatar
    Fr_Chuck Posts: 81,301, Reputation: 7692
    Expert
     
    #4

    Aug 28, 2011, 04:38 PM
    I think it was the evil cat next door but something chewed my unit at the early part of the summer, on my unit on the inside there was a inline fuse that blew. Things to look for.
    basec0m's Avatar
    basec0m Posts: 2, Reputation: 2
    New Member
     
    #5

    Aug 29, 2011, 06:22 AM
    Thanks guys... I was able to repair it. Replaced the fuse in the panel in the attic and saw that the green was unused. Bought some replacement cable, cut off the chewed portion, and spliced in a new piece. Connected the red/white to the yellows on the contactor and replaced the insulation.
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #6

    Aug 29, 2011, 03:16 PM
    Glad you got it fixed. Good job.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Dog Chewed Wires On Outside HVAC Unit [ 10 Answers ]

Hello. My puppy decided to chew the wires on my hvac unit outside. There are 3 wires. Red, Green, and White. I assumed that I needed to splice red to red, white to white, and green to green. I did that and the unit still does not come on outside. Any ideas? York Model H1RE036S06H Thanks...

Dog chewed computer wires [ 6 Answers ]

My dog and laptop were in the backseat of car together and he chewed through the cord that plugs laptop to electrical outlet. Am I out money or can I just patch it with electrical tape and use? Don't want to start a fire. BAD DOG! :eek:

My dog chewed my central air wires! [ 3 Answers ]

I turned on my Carrier central air today and it didn't work. I checked outside to find my dog chewed some of the wires! The wires coming out of the house are thin white and red wires (2)thatare banded together and the wires coming out of the condenser are blue and brown. How do I reconnect these...

Dog chewed wires [ 3 Answers ]

I just bought a new house and of course we had to get a new dog. Well he decided to chew and rip out the thermostat wire from the ac unit. I'm having trouble seeing where the wires are supposed to be connected inside the unit. I work on electronics for a living and this is confusing me. The...