    Water pump won't shut off
    For a few years, I've had the problem of my water pump not shutting off. I have a shallow well. The pump is located under my stairwell in my basement. The house is 12 years old.
    Last year, I had a plumber come in to fix it and they made an adjustment and it worked. Now I have a tenant there and the pump is not shutting off again. I need to get this fixed so that it's no longer an issue. If the adjustment(s) aren't working, I need to figure this out.

    If I go down and tap lightly on the electrical box on the side of the pump with a rubber hammer, it will shut off.

    Last year, the plumber mentioned it could be a faulty foot valve. But if it was, why would the tapping with a rubber hammer fix it, at least momentarily?

    I am unemployed right now so don't have money to spend on this so is there any solution that won't cost me too much? Thanks for any help you can provide.
    speedball1's Avatar
    speedball1 Posts: 29,301, Reputation: 1939
    Eternal Plumber
     
    #2

    Aug 5, 2011, 09:00 AM

    If I go down and tap lightly on the electrical box on the side of the pump with a rubber hammer, it will shut off.
    This tells me that your check/foot valve's OK but that the contacts in 56the control box are sticking in the closed position. My advice would be to replace the box but if you shut the power off at the breaker box and the points aren't burnt too bad you may be able to file the contacts clean.
    Good luck, Tom

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Well Pump shut off for 2 days, no water [ 6 Answers ]

So I recently bought my first home on septic and well. I found the filter and UV light systems installed with plastic braided hose and hose clamps, was a terrible job and weeped all over the place, took it upon myself to change this all out and hard pipe it in. I tried to isolate the pressure tank...

Jet well water pump will not shut off [ 1 Answers ]

Have a shallow dug well. The well ran completely dry. Before I realized it, used all of the water in system including hot water tank.Finally got water in well -2 months later.Had to prime pump to get water. Couldn't gt the primer plug out so had to take hose off the pressure tank to prime. Now...

Water pump won't shut off [ 2 Answers ]

I just installed a shallow well pump, It has a sand point in an existing well in my garden, The pipe is 18' in the ground and there is 11' of water in the pipe, I primed the pump and have good water pressure, I installed the pressure tank and put on a new pressure switch, The pump won't shut off. I...

Water pump won't shut off [ 7 Answers ]

Hi, I have had this problem for 3 weeks now and is about to kick the bucket. I am not a well specialist by any means but I have some plumbing knowledge. It all started with the pump not shutting off. The pressure will only go up to 30 psi and stay there until I shut it off manually. I have a...

Water pump will not shut off [ 12 Answers ]

My water pump will not shut off. The other day my water run out so I had to prime the pump. I got water back but now it won't shut off on it's own. I can manually shut it off from the pressure switch. I noticed the pressure gauge will reach a certain point to turn on but then seems stuck there. It...