    Pressure continuse to rise
    Well pressure switch set at 30 to 50 lbs. off at 50. Pressure continues to rise to 90 to 100lbs. ( no power to switch have shut off breaker.)well pump 1/2 h.p
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #2

    Jul 17, 2011, 08:05 AM

    ( no power to switch have shut off breaker.)
    What does that mean? You have to have power to the switch for the pump to run.

    Possible causes of problem
    1. Debris blocking port of the switch or the piping to the switch
    2. Defective switch
    3. Points of switch welded together

    Suggested solutions

    Turn off breakers, drain tank. Remove switch, inspect switch input port and piping. Clean and remove any scaling, rust or debris, or replace switch. They are not expensive.
    If switch is mounted on well piping, cover opening, turn on breakers briefly and flush piping. Reinstall switch and turn on breakers.

    If switch functions from a small tube from tank remove tubing and make sure it is clear by running a small wire through it.

    If you decide to replace switch make sure that it matches the pressure settings of the tank or re-pressurize the tank to match the switch settings.
    don.e's Avatar
    don.e Posts: 2, Reputation: 1
    New Member
     
    #3

    Jul 17, 2011, 12:18 PM
    Well pressure rise to 100lbs
    Problem ; well pressure switch set 30-50lbs pressure switch shuts off at 50 lbs.and pressure continues to rise to 95 to 100 lbs I can switch breaker off to pump after pressure switch shuts off it still climbs to 95 to 100lbs new pump was just put .they said it was gauges put new ones on old gauges read the same the well pump is 1/2 h.p submersible some said pressure switch located to far from pump app. 40 feet.old pump stater acting up but never had this problem? Old pump was 35 years old that why I put new one in .thanks
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #4

    Jul 17, 2011, 12:54 PM

    You already have this question posted. If you want to add something go to your original post and type in the box at the bottom of the screen
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #5

    Jul 17, 2011, 02:13 PM

    How far is pressure switch from tank?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

What is the ratio of the rise to the run if the rise is 3/2 and run is 5 [ 1 Answers ]

What is the ratio of the rise to the run if the rise is 3/2 and run is 5

Price rise [ 1 Answers ]

Hi can some answer my question What is the reson for the price hike for all the products every year Why is it not decresing Can any one explain

Pay rise [ 2 Answers ]

Hey, does anyone know if there is a law about payrises. Such as its been 6 years since someone I know had one even though they have been with the same employer for at least 20 years. Any feedback would be gratefully received.

This woman is trying to get a rise out of me [ 8 Answers ]

Ok, we're both new hires, the chick is hot and single. And I'm hot and single. We both know it. I express no interest in her what so ever. She complains to me about her failed relatinoships and how she's given up on men. Im the nicest guy she's ever met (I think that's the problem). I...


View more questions Search