    Pumptrol Adjustment?
    My switch does not turn on when the taps are running even when the water has stopped coming out. I usually have to push the contacts together to get it to work
    hkstroud's Avatar
    hkstroud Posts: 11,929, Reputation: 899
    Home Improvement & Construction Expert
     
    #2

    Jun 21, 2011, 02:24 PM

    Probably blocked pipe or tubing to the pressure control switch.
    Turn off power, open faucet to relieve pressure, remove switch from piping or disconnect tubing from tank to switch. Inspect and clean inside pipe and opening to switch.
    jlisenbe's Avatar
    jlisenbe Posts: 5,020, Reputation: 157
    Uber Member
     
    #3

    Jun 21, 2011, 03:11 PM

    While you have the switch off, replace it. They are relatively cheap (25 bucks) and it's not worth the headache to remove the switch, clean out the pipe, hook everything back up, and turn on the breaker, only to find out that it was the switch all along and not the pipe.

    But HK is entirely correct. The little pipe can get clogged and cause the switch to become sluggish. Check it out. Replace them both.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Pumptrol Pressure Regulator adjustment [ 12 Answers ]

How do I adjust the pressure regulator on a Pumptrol to increase the amount of pressure?

Pumptrol adjustment Cut-off too high [ 2 Answers ]

I've been struggling with my Pumptrol (Square D 9013FSQ 2) pressure switch for hours, and fails to solve my pressure issue. It had somehow drifted, and was kicking in at 15 lbs (way too low) and off at 70 lbs (way too high). I'm aiming for 40-60, so I turned the small nut counter-clockwise and...

Pumptrol Pressure Regulator adjustment [ 5 Answers ]

Actually, the smaller control sets the differential amount between the low and high cutoffs, that is usually a 20lb difference, such as 30lbs "turn on" to 50lbs "turn off" (the default factory settings), or 40-60, or 45-65, etc. and you really should not mess with it. Just adjust the longer...

Pumptrol Square D seetings/Amtrol wx-203 precharge adjustment [ 3 Answers ]

So, at 3 am when I'm trying to sleep the jet pump clicks on just for a moment , then a few minutes later it clicks on again momentarily, repeat, repeat... This probably happens at other times as well, but it's not so annoying then; then I can ignore the problem. Also, sometimes the Pumptrol needs...

Pumptrol? Help please [ 5 Answers ]

Hello there. I'm completely new to pumps and plumbing, so please bare with me. My family owns a water pump business. We fill 5gallon jugs and such. Recently, our machines don't vend water consistently anymore. The pressure would drop and we'd have to manually work the machine to regain psi to...