    HVAC noise at returns
    I have loud returns and I was hoping somebody could take a look at this and give suggestions on reducing the noise.

    Three Story House Approx 2100 sq foot between 1st & 2nd Floor:

    Unfinished Basement:
    Comfortmaker system. Filter right by blower. Return splits with one going to 1st floor and one going to the second floor. Ductwork going to 1st fl is 16 x 10. Ductwork going to 2nd floor is 12 x 10

    1st Floor, Open Floor concept:
    Ductwork comes from basement (16 x 10) and stops half way up the wall. Return grill is 16 x 16 and is at the bottom of the wall. This return is loud when it kicks on. Have to turn up volume on TV. I took the grill off and the noise is the same.

    2nd Floor:
    Ductwork comes from basement (12 x 10) and return is in the master bedroom and is 12 x 12 grill. There is also a return in the loft above the stairs in the ceiling. This return connects to the 12 x 10 ductwork through flexduct in the attic. This return pretty much draws no air. When I take the grill off the return in the master the noise is the same and I can't feel any air coming down when I stick arm up the ductwork. It seems all the air is rushing at the bottom of the opening.


    I'm not sure if I don't have enough ductwork? Can I just get a quieter blower? Should the return in the loft be connected to the return in the master? Can I just put filters on the return grills? Anything I can add to the ductwork to soften sound? Even though the basement is unfinshed I use it like it is finished. Should I have a return and registers installed in the basement?

    Just ask for any other info. Thanks in advance.

Check out some similar questions!

Hvac, air returns [ 3 Answers ]

My cold air returns have vents that can be closed but the warm air returns can't be closed. Is this right? Barry

HVAC furnace noise [ 2 Answers ]

I have a fairly new house 2years old , the intake -exhaust from the furnace runs through the attic , through a 3" pvc concentric , everything works fine , however there is a "tapping"noice that comes from the concetric as the pipe heats up , its fairly loud because it echoes in the exhaust pipe ,...

HVAC Vent Noise [ 5 Answers ]

I recently had my HVAC system replaced and now I am having a problem with the noise being generated by the room vents. It is probably because this newer system (the previous was >30yo) has a stronger fan motor and is forcing the air through the vents faster. It is really annoying and wakes us in...

HVAC cold air returns in Basement [ 1 Answers ]

What size of cold air return should I use on th ebasement approx 700squre feet two separate room with two heat vents in each 4" will do per room?? Thanks

HVAC cold air returns [ 2 Answers ]

Should I install Cold air returns in my finished basement I have a force air 90 percent furnace Thanks Jim


View more questions Search
 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.