    Plumbing water tank relation to cold water pressure?
    I have shut off the main water feed at the road, shut off the main disconnect in the house to do an outside faucet line repair. I've got all the new pieces sweated into place, except for one. Back flow water continues to drip out of this one connection, preventing me from making my last solder. I can't make this water completely shut off, though I've opened and closed every cold water line in the house. One odd thing... if I open the pressure relief valve on my hot water tank most of the cold water faucets in the house begin to run rather consistently. Weird huh?
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #2

    Jun 4, 2011, 10:49 AM

    Hi Crd...

    You said, " opened and then closed" every water line. Here is probably where your issue is... ;)

    OPEN all faucets and leave them all open until it is time to fill/test the system.

    If the issue continues, shut the cold water shutoff into the water heater (so hot water can't be pulled back into the cold water) and then, only if needed, disconnect the water meter and drop it out for a few minutes while you make the final solder joint... should work!

    Worst case, go get a couple sharkbite or gatorbite PUSH FIT type fittings and connect your piping using these fittings that do not require any soldering (available at all home improvement stores).

    Let us know how you make out, OK?

    Mark

    PS: Be sure to keep the new outside faucet open while soldering, too!!
    CURaiderDude's Avatar
    CURaiderDude Posts: 4, Reputation: 1
    New Member
     
    #3

    Jun 5, 2011, 06:57 AM
    Comment on massplumber2008's post
    You were right on Mark. It was hot water backing up into cold water intake line. Once I finally got the final leaking to stop the solder still wouldn't work, so (like you said) a compression fitting was the solution. All works great now! Thanks for your help! Rob
    CURaiderDude's Avatar
    CURaiderDude Posts: 4, Reputation: 1
    New Member
     
    #4

    Jun 5, 2011, 07:05 AM
    Hot water was backing up into the cold water intake line. I shut off the hot water tank cold water intake valve, after draining about 15 gallons of hot water from the tank (to help relieve the pressure). I still couldn't get the solder to work on the last, tricky connection, so a compression fitting did the trick (no solder required). So a compression fitting was the solution.
    KenSayers's Avatar
    KenSayers Posts: 16, Reputation: 2
    New Member
     
    #5

    Jun 6, 2011, 06:30 AM
    Comment on CURaiderDude's post
    For future use, to stop slight drips from fouling up your sweating of fittings, I will cram a bit of white bread into the line. That stops the water long enough to solder and then dissolves in the water. Note, do not use the crust.
    CURaiderDude's Avatar
    CURaiderDude Posts: 4, Reputation: 1
    New Member
     
    #6

    Jun 6, 2011, 06:48 AM
    Comment on CURaiderDude's post
    Ah, yes... good advice.
    massplumber2008's Avatar
    massplumber2008 Posts: 12,832, Reputation: 1212
    Senior Plumbing Expert
     
    #7

    Jun 6, 2011, 07:32 AM

    I guess if homeowner wanted to try the bread they could, but it really shouldn't be necessary.

    If you open all faucets and drain the water from the system, and shut the cold water feed into the water heater then you should be all set.

    I have trained probably 50-60 commercial/residential apprentices/plumbers over the years and whenever they had issues with soldering I could always come along and resolve it by simply draining everything, isolating boilers/water heaters or, worst case, dropping the water meter itself.

    Thanks for posting guys!

    Mark

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Replaced a hot water tank,water is not going to the pressure tank-the pump stays on [ 2 Answers ]

Replaced a hot water tank, turned the pump on and the water is bypassing the pressure tank. The pressure tank will not fill up and the pump remains on and will not shut off. We do get water though but needs to shut off the pump so it will not burn out. Any thoughts? Thank you Any ideas will...

No cold water pressure in my tank, why [ 1 Answers ]

All of sudden there is no cold water pressure in the bathroom; sink taps or shower. Why would that be? We have "closed water tank system" which we have to blead every 3 months or so to establish a decent pressure, as the tank is not high enough to maintain pressure. I hope you can suggest...

Low cold water pressure after plumbing repair? [ 6 Answers ]

Hello! My water line was shut off for a repair. Now that the water is back on, the cold water pressure in the upstairs bathroom has dropped. The hot water pressure upstairs is fine, and the cold water pressure on the main floor and the basement is fine. How do I troubleshoot this? Could...

Does the pressure from the hot water tank effect the pressure of the cold water? [ 2 Answers ]

We have very low water pressure at our kitchen sink from both the cold and hot water faucets, but no problem with the water pressure to the bathroom or washer. The cold water tank is closest to the kitchen and the hot water heater is near the bathroom and washer. Someone told my roommate that there...

Bathroom water pressure vey poor from cold water storage tank [ 1 Answers ]

Bathroom toilet is very slow to fill up also cold water tap in bathroom when turned on has little or no water coming out of it.can you reply staight away please.


View more questions Search